Install In-Line Pump and Assemble
Supply Line
1. Place In-Line Pump on the platform as shown.
2. Connect the upper port of the strainer basket to the union.
Hand-tighten ONLY.
3. Connect two 1-1/2" (3.81 cm) couplings; One to the outlet
side and another to the inlet side of the filter. Cut two
lengths of 2 1/2” (10.16 cm) from 1-1/2" (3.8 cm) dia. PVC
pipe. Install one end of pipe to strainer basket union and
the other end to the 1-1/2" (3.8cm) coupling on the outlet-
side of the filter.
NOTE: Install filter with the arrow pointed in the direction of
water flow (toward the In-Line Pump).
4. Connect the other 2 1/2"(10.16cm) length piece of pipe to
the inlet-side of the filter and to the ball valve.
Pump
1 ½" Ball Valve
(1009-0101)
PVC Tee Reducer
1 1/4"x 1 1/4"x 1 ½"
(1021-0134)
PVC Elbow 1 ½"
(1021-0106)
Strainer
(1062-5017)
In-Line Filter
(1049-0100)
PVC Elbow 1 ½"
(1021-0106)
1 ½" Ball Valve
(1009-0101)
Pump Union
(1021-6023)
11" pipe
52" pipe for a 4 ft System
64" pipe for a 5 ft System
76" pipe for a 6 ft System
4" pipe
9" pipe
4" pipe
2 1/2" pipe
1 ½ Union
(1021-0110)
6" pipe
Water Tank
(0406-8196)
PVC Reducer
1 1/4"x 1 1/2"
(1021-6016)
1 ½" Ball Valve
(1009-0101)
PVC Elbow 1 ½"
(1021-0106)
Water Tank
Cover
(0406-8197)
Pump Support Bracket
(0404-8368)
1" Ball Valve
(1009-0101)
5" pipe
PVC Fitting
(1021-0109)