Warning, Electrical requirements wiring – Hired-Hand Universal Ray Tube Heaters: AG1 Series User Manual
Page 7

WARNING
!
!
Electric Shock
Field wiring to the tube heater must be connected and grounded according to the guidelines
in the Tube Heater General Manual, Series Insert Manual and in accordance with national,
state, provincial and local codes. In the United States refer to the most current revisions to
the ANSI/NFPA 70 Standard, and in Canada refer to the most current revisions to the CSA
C22.1 Part I Standard.
• 120 Volt - 60 Hz GRD, 3-wire.
• Starting current 4.8 amps.
• Running current 1.1 amps.
• 120 Volt control voltage.
7
2.0
Installation • Wiring
Electrical Requirements
Wiring
AG1
Series
Figure 2.2
•
Field Wiring Diagrams
A. Multiple Heaters, Single Control.
Burner Control Box
Burner Control Box
Black
Panel
Ground
White
Black
Panel
Ground
White
120V Barn Controller
120V Out
120V In
L1
N
Green
Green