Hired-Hand Super-Savers (Forced Air Heaters) XL: Outside Mounting Kit User Manual
Heater outside mounting kit, Hh-ss-series heaters and ss-series heaters, Description
HIRED-HAND MFG., INC.
• 1733 Co Rd 68 • Bremen, Alabama 35033 • Phone 256-287-1000 • Fax 265-287-2000
Manual Part Number 4801-0101 Rev. 3-08
Page 1 of 4
Figure 1 - Guide for Locating OSM Heater on Wall
24 1/2”
25”
23 1/2”
4”
6 1/2”
30”
1”
1 1/2”
10 5/8”
Outline of Heater
Facing Outside
Wall of Building
Outline of
Hole for
Thru-Wall
Duct
Allow 16”
accessibility
clearance
for doors on
each side if
desired.
Allow 16”
accessibility
clearance
for doors on
each
side if
desired.
Outline of
Mounting
Bracket
16”
16”
Dimensions for HH-SS-Series Heaters
Dimensions for SS-Series Heaters
HH-SS-Series Heaters and SS-Series Heaters
Detail 1A
Detail 1B
DESCRIPTION
Hired-Hand heaters are available in Outside Mount (OSM) models. These heaters are designed to be mounted to the
outside wall of a building. This saves valuable space inside the building and ensures fresh air intake for the heater. If
you have purchased one of our OSM heaters, please read the following before installing or operating your new heater.
A template is printed on the heater carton. Use the template or these instructions to mount the heater.
Note: Different instructions are provided depending upon whether you are installing a HH-SS-Series heater or you are
installing a SS-Series heater. See the heater nameplate for the model of heater you are installing.
TOOLS REQUIRED
INSTRUCTIONS
1. Use Figure 1 as a guide for locating the heater on the wall. Choose dimensions that match the heater model you
are installing. Refer to the installation instruction manual provided with the heater to determine minimum
clearances to combustibles. Note additional clearance on sides of heater may be desirable for maintenance
accessibility. When locating heater on wall the thru-wall duct should be centered between wall studs if possible.
Power Drill
Level
1/4" Drill Bit
Tape Measure
Hole Saw
HEATER OUTSIDE MOUNTING KIT
24 1/2”
25”
25 1/2”
4”
4 1/2”
30”
1”
1/2”
10 5/8”
Outline of Heater
Facing Outside
Wall of Building
Outline of
Hole for
Thru-Wall
Duct
Allow 16”
accessibility
clearance
for doors on
each side if
desired.
Allow 16”
accessibility
clearance
for doors on
each
side if
desired.
Outline of
Mounting
Bracket
16”
16”