beautypg.com

Hired-Hand Super-Savers (Forced Air Heaters) XL: White-Rodgers Ignition Control Module User Manual

For 120vac super-saver heaters, Ignition control modules, Replacement kit number

background image

White-Rodgers Ignition Control Module

Replacement Kit

for 120vac Super-Saver Heaters

HIRED-HAND, INC.

• 1733 Co Rd 68 • Bremen, AL 35033 • Phone 256-287-1000 • Fax 256-287-2000

Manual Part No. 4802-5086 rev 10-03b Page

1 of 6



















FIGURE 1

Ignition Control Modules


DESCRIPTION

This kit is provided to replace damaged ignition control
modules on Hired-Hand’s early model Super-Saver
heaters. The kit includes a replacement Ignition Control
Module and additional wire harnesses necessary to
replace a White Rodgers 50E47-160 model control
module with a UT 1018-500 (HHI Part Number 3591-
1851) replacement module.

The White-Rodgers Ignition Control Module Replacement
Kit is supplied with a UT 1018 module, three precrimped
wire Assemblies and crimp terminals.

When the module kit is received, check for shipping
damage or missing parts.

The NEW 1018 module does not have the PCB mounted
2-pin male connector as shown on the OLD 160 module.
Once the 160 module is removed, the female 2-pin
connector will be cut off and replaced with female crimp
terminals.



Replacement Kit Number

Part Number

Model

6450-5250

White Rodgers Ignition Control Module

Replacement Kit

Tools Required

Philips Screwdriver

Nut-Driver Set

Flat-Head Screwdriver

Needle Nose Pliers

Sta-Con Crimpers

Wire Strippers

NOTE

Do Not Use These Wiring Instructions To Replace

Any Other Ignition Control Module Except White

Rodgers Model Number 50E47-160.

DANGER

HAZARDOUS VOLTAGES

Failure To Follow These Instructions May Result in Injury
Or Death!
• Only A Certified Electrician Should Replace the

Ignition Control Module.

• Do Not Clean Or Perform Maintenance Without First

Unplugging The Power Cord And Turning OFF The
Gas Supply.

• Ensure All Cables And Wiring Are Placed And

Secured Before Turning Power And Gas ON.

• Do Not Spray Water Or Other Liquids Directly On Or

Near The Control Module And The Igniter Assembly.


!

OLD 160 Module

NEW UT 1018 Module