VALVE

PS

PRESSURE

SWITCH

V

WARNING

!

!

Placement of explosive objects, flammable objects, liquids and vapors close
to the heater may result in explosion, fire, property damage, serious injury or
death. Do not store or use explosive objects, liquids or vapor in the vicinity of
the heater.

Clearance to combustibles is defined as the minimum distance that must exist between the tube surface,
or reflector, and any combustible items (see Figure 1.1). It also pertains to the distance that must be
maintained from moving objects around the tube heater. When installing the tube heater system, clearances
to combustibles for the Series tube heater and configuration must be maintained.

Clearance to Combustibles

AVOID EQUIPMENT FAILURE

THIS 10 FT. TUBE IS THE

COMBUSTION CHAMBER.

THIS TUBE MUST BE THE FIRST TUBE

FOLLOWING THE BURNER CONTROL BOX.

!

INSTALLER

The combustion chamber utilizes either 409

stainless, titanium alloy or aluminized steel -

depending on the model number of your heater.

Rotate the tube’s welded seam to bottom.

Consult the manual(s) for further details.

4

1.0

Safety • Safety Labels and Locations • Clearance to Combustibles

AG1

Series

SERVICE ACCESS PANEL

IGNITER & FLAME SENSE COMPARTMENT

1. Turn off gas & electricity.

2. Remove cover by lifting top

cover upward and outward.

CAUTION: HOT SURFACE.

KEEP COVER IN PLACE. REMOVE FOR SERVICE ONLY.

SERVICE ACCESS PANEL

IGNITER & FLAME SENSE COMPARTMENT

1. Turn off gas & electricity.

2. Remove cover by lifting top

cover upward and outward.

CAUTION: HOT SURFACE.

KEEP COVER IN PLACE. REMOVE FOR SERVICE ONLY.

INSTALLER

***AVOID EQUIPMENT FAILURE***

THIS 10’ TUBE IS THE

COMBUSTION CHAMBER.

THE COMUSTION CHAMBER UTILIZES

EITHER 409 STAINLESS TITANIUM OR ALUMINIZED

STEEL - DEPENDING UPON THE

MODEL NUMBER OF YOUR HEATER

THIS TUBE MUST BE THE FIRST TUBE

FOLLOWING THE BURNER BOX.

MOUNT WELDED SEAM TO BOTTOM

CONSULT IOM OR PACKAGING STICKER FOR DETAILS

F/N: LLTB004

(orange)

F/N: LLTB026

Right Panel

(Valve Compartment)

Secondary Combustion

Chamber (if applicable)

Primary Combustion

Chamber

16” Burner

Tube

Left Panel

(Fan Compartment)

F/N: LL01 - Clearance Safety Tag

(Affix adjacent to heater’s thermostat)

F/N: LLV3EP6

ALUMINIZED TUBE

(This is the Second Chamber)

This tube is constructed of aluminized coated steel and must be

placed directly after the titanium coated “Combustion Chamber”

(orange labeled tube)

Used on Models: XTS, DET(-3), DES(-3) (150-200 MBH) ONLY

ALUMINIZED TUBE

(This is the Second Chamber)

This tube is constructed of aluminized coated steel and must be

placed directly after the titanium coated “Combustion Chamber”

(orange labeled tube).

150,000 BTU/H models only