Hired-Hand Super-Savers (Forced Air Heaters) XL: Igniter Replacement User Manual
Igniter replacement, Directions, Warning

Hired-Hand Mfg., Inc. • 1733 County Road 68 • Bremen, Alabama 35033 • Phone 256-287-1000 • Fax 256-287-2000
Sheet Part No. 4801-0142 Rev 2-07
CAUTION! Be sure that heater is cool before touching internal surfaces. These surfaces remain
hot enough to cause severe burns during and after operation.
Tools Required
11/32" Nut Driver
Materials
NOTICE: Igniter in kit depends upon operating voltage of heater unit (either 120 or 240 VAC)
Directions
1. Disconnect power to the heater.
2. Disconnect the two lead wires from the existing igniter. Remove the 8-32 kep lock nut. Remove the
igniter
from the existing bracket. You will then be ready to install the new replacement bracket by
referencing one of the above figures.
3. If you have a 120,000 btu unit heater or larger then you will need to reference Figure-1 before installing
the replacement bracket. Remove the 8-32 kep lock nut and the flame probe from the existing bracket.
Once the flame probe is removed you are then ready to attach the replacement bracket and replace the
flame probe to the existing bracket. Secure them in place using two 8-32 kep lock nuts.
4. If you have a 75,000 btu unit heater or smaller then you will need to reference Figure-2. Attach the
replacement bracket and secure it in place using 8-32 kep lock nut.
5. After attaching the replacement bracket to the existing bracket insert the new igniter as shown in Figure-
3. Use 8-32 x ½
″ machine screw and nut to secure the igniter to the bracket.
6. Be sure the tip of the igniter extends over the top of the cast iron burner. Also be sure that the igniter
does not contact cast iron burner or heater internals.
7. Reconnect the wire leads from the harness to the new igniter leads.
8. Connect power to the heater, and check for proper operation.
9. Installation completed.
Voltage Part
No.
Quan.
Description
Voltage 120 VAC
3002-5000
1
IGNTR 120 vac Mini 2.5” Hot
Voltage 240 VAC
3002-5001
1
IGNTR 240 vac Mini 2.5” Hot
1001-2597 3 8-32
kep
nut
1004-0118 3 8-32 x ½
″ machine screw
0408-4390
1
FAB AS Brkt kit 2.5” Igniter
Igniter Replacement
Warning!
Disconnect All Electrical Power Sources To Heater Before Installing Igniter
Super Saver
®