Hired-Hand Super-Savers (Forced Air Heaters) XL: Capacitor Replacement User Manual
Capacitor replacement, Warning
HIRED-HAND, INC. • 1733 Co Rd 68 • Bremen, AL 35033 • Phone 256-287-1000 • Fax 256-287-2000
Sheet Part No. 4802-0538
Capacitor Replacement
120,000+ BTU Large Heaters
CAUTION! Be sure that heater is cool before touching internal surfaces. These surfaces
do stay hot enough to cause severe burns during operation.
Removable Mounted Capacitor (See Fig. 1)
Non-Removable Mounted Capacitor (See Fig. 2)
1.
Disconnect All Electrical Power.
2.
Remove nut and capacitor.
3.
Disconnect wire leads from old
capacitor and connect to new capacitor.
4.
Install new capacitor
and replace nut.
Capacitor
Nut
Fig. 1
1.
Disconnect All Electrical Power To Heater.
2.
Disconnect leads from old capacitor and
connect to new capacitor
.
3.
From the top right corner of the motor mount plate,
measure down 1 inch and over 1-1/2 inches. Mount new
capacitor to the motor mount plate with two self-tapping
sheet metal screws. See Fig. 2.
Warning!
Warning!
Disconnect All Electrical Power Sources To Heater Before Installing Capacitor
Fig. 2
1 in.
1-1/2 in.