beautypg.com

Ratings and specifications 1.1. ratings, Model no. maximum input minimum ventilation, Gas pressure requirements – Hired-Hand Bunsen Jet Brooders: Super-Saver Bunsen Jet (Radiant Brooder with Pilot Ignition) User Manual

Page 3: Caution! minimum clearances, Lp/propane gas, Natural gas

background image

Super Saver Bunsen Jet Brooder with SPI

1

1.

Ratings and Specifications

1.1. Ratings

Model No.

Maximum Input

Minimum Ventilation

(Air required to support combustion)

BJ-C-32-SPI

32,000 BTUH

(9.38 kW)

320 CFM/brooder

(543.6 m

3

/hr)

BJ-C-42-SPI

42,000 BTUH

(12.31 kW)

420 CFM/brooder

(713.6 m

3

/hr)

1.2. Gas Pressure Requirements


Burner manifold gas pressure is to be 11 in. W.C. [27.4
mbar] at maximum input rating. Gas pressure should be
checked by a certified gas technician, with maximum load on
supply and while brooder is in operation.

Burner manifold gas pressure is to be 7.0 in. W.C. [17.4
mbar] at maximum input rating. Gas pressure should be
checked by a certified gas technician, with maximum load on
supply and while brooder is in operation.


1.3. Caution! Minimum Clearances

These minimum clearances are calculated to show the safe operating boundaries. Do not operate
the brooder with walls, floor, ceiling, or other combustible objects within these limits.

Model

Ceiling

Wall

Floor

BJ-C-32-SPI

36 inches

(92 cm)

36 inches

(92 cm)

48 inches

(122 cm)

BJ-C-42-SPI

36 inches

(92 cm)

36 inches

(92 cm)

48 inches

(122 cm)

LP/Propane Gas:

Natural Gas: