Hired-Hand RollSeal Rollup Curtains: ROLLUP CURTAIN SYSTEM Rev 12-07 User Manual
Page 8

Part No. 4801-5169 Rev 12-07
Rollup Curtain System
Page 8
8" C-channel
C
See Table 3
D
See Table 3
1ft (30cm)
Minimum
8" C-channel
8" C-channel
5.3.2 Double Stack System Framing
NOTE: The System Cabinet is designed for use with 8" C-Channel.
Double stack framing provides for a two tier curtain system along the outside wall of building. Any two of
the systems in Table 2 may be used in the Double Stacked System. The curtain system attaches to
horizontal stringers. The bottom stringer should be at least 1 ft. (30 cm) above ground level. The middle
stringer must be installed at height D (see Table 3) above the top of the bottom stringer as shown in the
diagram above.
The top stringer should be installed at height C (See Table 3) above middle stringer as shown in the
diagram above. Pocket kits are available to enclose openings.
Top stringer
Middle stringer
Bottom stringer
Table 3 Double Stacked Rollup Curtain System Examples (Not all inclusive)
Stacked
System
Top
Dimension C
Bottom
Dimension D
Single
in.
cm
Single
in.
cm
8' Stack
4'
48.0
121.9
4'
48.0
121.9
8.4' Stack
4'
48.0
121.9
4.4'
52.8
134.1
9.4' Stack
4.4'
52.8
134.1
5'
52.8
134.1
10' Stack
5'
52.8
134.1
5'
52.8
134.1
10' Stack
4'
48.0
121.9
6'
72.0
182.9
10' Stack
6'
72.0
182.9
4'
48.0
121.9
11.4' Stack
6'
72.0
182.9
5.4'
64.8.0
164.6
12' Stack
6'
72.0
182.9
6'
72.0
182.9