5 ft.
(152 cm)
6.7 Installing Bottom Drive Pipe into Curtains
NOTE: Bottom pipe serves as drive pipe to attach motor drive.
1. Insert 1.9" (4.83 cm) O. D. pipe into bottom hem of curtains. Insert pipe into curtains for the entire length
of the system.
2. Fit fabric clips onto the bottom 1.9" (4.83 cm) pipe/curtain assembly. Install clips every 5 ft. (152.4 cm)
3. If installing a double stack system, repeat steps above to install second drive pipe into hem of top curtain.
NOTE: Drive Pipe/Curtain should end 12" (30.48 cm) from Drive Cabinet. See Section 7.
Figure 6
Bottom Rod & Fabric Clips
1.9" (4.83 cm) O.D.
GS Rod
See Parts list.
1.9" (4.83 cm)
O. D. GS Pipe
Bottom Hem
Of Curtain
- RollSeal Rolling Dampers (5 pages)
- RollSeal Rollup Curtains: Ridder Motor Control (9 pages)
- RollSeal Rollup Curtains: RollSeal Motor Controls (16 pages)
- RollSeal Rollup Curtains: ROLLUP CURTAIN SYSTEM Rev 11-05 (38 pages)
- RollSeal Sidewall System (Curtain): SideWall Curtain (38 pages)
- RollSeal Sidewall System (Curtain): Wiring Diagram And Limit Switches (2 pages)
- RollSeal Sidewall System (Curtain): Floating Hook & Loop Assembly (2 pages)
- Light Traps: Light Trap Fan Unit (2 pages)
- Light Traps: Light Trap Adapter Kit (2 pages)
- Light Traps: 54x54 Light Trap Air Inlet (2 pages)
- Light Traps: 7x44 - 8x44 Light Trap Air Inlet (1 page)
- Light Traps: Light Trap Vent Box Installation (1 page)
- Light Traps: Installing Continuous Light Trap (6 pages)
- Light Traps: Installing Light Trap for Fan (4 pages)
- Light Traps: Light Trap Fan Unassembled (4 pages)
- Baffles, Vents, & Inlets: VENT DOORS Installation (2 pages)
- Baffles, Vents, & Inlets: GRAVITY VENT DOOR Installation (2 pages)
- Baffles, Vents, & Inlets: SINGLE CEILING INLET (2 pages)
- Baffles, Vents, & Inlets: 24 & 36 Chimney Vent (12 pages)
- Baffles, Vents, & Inlets: Vent Kit for Generation Structures (8 pages)
- Baffles, Vents, & Inlets: QUAD CEILING INLET (2 pages)
- Baffles, Vents, & Inlets: Ridge Vent Assembly Instructions (2 pages)
- Baffles, Vents, & Inlets: Installing Ceiling Inlets (2 pages)
- Tunnel Doors (16 pages)
- Circulation and Stir Fans: MEGA-FLOW FANS (See Reverse Side for Framing Formats) (2 pages)
- Circulation and Stir Fans: MEGA-FLOW 24 INCH ORIFICE STIR FANS (2 pages)
- Circulation and Stir Fans: MEGA-FLOW ORIFICE FANS (2 pages)
- Circulation and Stir Fans: Post Mount Assembly For 52 Orifice Fans (4 pages)
- Circulation and Stir Fans: Funnel Flow Fan (1 page)
- Circulation and Stir Fans: MEGA FLOW FANS Round Dairy Fan (2 pages)
- Circulation and Stir Fans: 48 MEGA FLOW (2 pages)
- Circulation and Stir Fans: 48 MEGA FLOW Galvanized (2 pages)
- Circulation and Stir Fans: MEGA FLOW 36 (91 cm) Fan Housing (2 pages)
- Circulation and Stir Fans: 48 MEGA FLOW Fan Housing (2 pages)
- Circulation and Stir Fans: 52 Orifice Fan HSP Conversion Kit (2 pages)
- Circulation and Stir Fans: HAF Fan Mounting Bracket Installation (2 pages)
- Circulation and Stir Fans: POST MOUNT KIT ASSEMBLY (2 pages)
- Circulation and Stir Fans: MEGA FLOW Motor Replacement 36 (91 cm) Fan Housing (2 pages)
- Mega Flow Panel Fans: Econo-Flow 48 Belt Drive Panel Fan (2 pages)
- Mega Flow Panel Fans: Power Cord Installation (2 pages)
- Mega Flow Panel Fans: BELT TENSIONER 48 Mega Flow Fan (1 page)
- Funnel Flow Fans: Belt Tensioner (2 pages)
- Funnel Flow Fans Rev 12-03 (2 pages)
- Funnel Flow Fans Rev 10-98 (1 page)