Installation – Hired-Hand RollSeal Rollup Curtains: ROLLUP CURTAIN SYSTEM Rev 12-07 User Manual
Page 7

Part No. 4801-5169 Rev 12-07
Rollup Curtain System
Page 7
1 ft (30 cm)
Minimum
Top stringer
Bottom stringer
5. Installation
5.1 Tools Required
3/8 in. (10mm) power screwdriver
Pop rivet gun
Ladder
3/16 in. (5 mm) drill bit and power drill
Hammer
Carpenter's level
Electric saw with metal cutting blade
Chalk line
Tape measure
5.2 Receipt and Inspection of Parts
The RollSeal RollUp Curtain System is shipped as parts that require assembly.
Identify components by the Parts/Assemblies section in back of this manual. When components are received, check
for damaged, loose or missing parts. If there are damaged or missing parts, contact your RollSeal distributor
immediately. For efficient installation, follow steps in order presented in this manual.
Please read the instructions carefully before beginning installation.
5.3 Framing
A single rollup curtain system may be installed or a double stack rollup curtain system may be installed. Review the
following descriptions of single framing and double stack framing. Adjust your framing members as required to fit
the size system that you are installing.
5.3.1 Single System Framing
NOTE: The System Cabinet is designed for use with 8" C-Channel.
Single framing provides for a one tier curtain system along
the outside wall of building. The curtain system attaches
to horizontal stringers. Bottom stringer should be at least
1ft. (30cm) above ground level.
The top stringer should be exactly at height B (See Table
2) above the bottom stringer as shown in the diagram
above. Install or adjust top stringer to this specification.
Pocket kits are available to enclose openings.
8" C-Channel
B
See Table 2
8" C-Channel
Table 2 Single Rollup Curtain Systems
System Dimension
B
in. cm
4' Single
48.0
121.9
4.4' Single
52.8
134.1
5' Single
60.0
152.4
5.4' Single
64.8
164.6
6' Single
72.0
182.9