HATZ Diesel 4M42 User Manual
Page 96

Type of fault
Possible causes
Remedy
Chapter
Fuel prefilter is
clogged.
Change the fuel
prefilter.
8.2.9
Changing
the fuel pre-
filter,
page 72
Fuel filter is clog-
ged.
Change the fuel fil-
ter.
8.2.14
Change the
fuel filter,
page 83
Fuel supply is inter-
rupted.
Systematically
check the entire
fuel supply.
Stop signal from
monitoring ele-
ments that are as-
sociated with the
automatic switch-
off (additional
equipment):
▪ No oil pressure.
▪ Dirty air filter
unit.
▪ Faulty three
phase alternator.
▪ Check the oil lev-
el.
▪ Check the de-
gree of dirt con-
tamination of the
air filter, and
clean or renew it
if necessary.
▪ Contact the Hatz
service station.
7.9 Check-
ing the oil
level and
adding oil if
necessary,
page 53
8.2.10
Maintaining
the dry air
filter,
page 74
Engine switches off
spontaneously dur-
ing operation.
The tank ran out of
fuel during opera-
tion
Fill with fuel.
Fuel prefilter or fuel
filter is clogged.
Change the filter.
8.2.9
Changing
the fuel pre-
filter,
page 72
8.2.14
Change the
fuel filter,
page 83
Faults
2-4L41C, 2-4M41, 2-4M41Z, 4L42C, 4M42
96
Operator's Manual
HATZ