HATZ Diesel 4M42 User Manual
Page 85

Step
Activity
10
Perform a leak tightness test by activating the manual lever.
11
After completion, insert the access cover to the fuel feed pump
back in the side wall.
12
Mount the capsule and air guide parts again.
Overview 4L42C and 4M42
Pos.
Designation
1
Drain plug
Preparation 4L42C and 4M42
Step
Activity
1
Close the fuel lines on the filter housing.
2
Place a suitable container under the filter to collect emerging
fuel.
3
Release the drain screw (1) and drain the fuel.
2-4L41C, 2-4M41, 2-4M41Z, 4L42C, 4M42
Maintenance
HATZ
Operator's Manual
85