4 specifications, Power, Analog specifications – Rice Lake Condec UMC600IS User Manual
Page 43: Serial communications, Operator interface, Environmental, Enclosure, Certifications and approvals
40
UMC 600IS Installation Manual
6.4
Specifications
Power
Power Input
Intrinsically safe power supply (7.5 VDC
output) or optional 6 VDC battery
Analog Specifications
Full Scale Input Signal
Up to 45 mV
Load Cell Excitation
5 VDC, fixed
Load Cell Current
60 mA (4 x 350 Ω load cells)
Load Cell Cabling
6-wire configuration with
remote sensing
Analog Signal Input Range
0.7 mV/V to 3.2 mV/V
Analog Signal Sensitivity
0.3 µV/graduation
Resolution
10 000 dd (NTEP), 80 000
expanded
Measurement Rate
10 measurements/sec
Display Increments
1, 2, 5, 10, 20, 50, 100
Decimal Point
0, 0.0, 0.00, 0.000, 0.0000
AZM (Zero Tracking)
Gross
mode
only:
configurable to ±0.5 grads,
±1.0 grads, ±3.0 grads, or off
PAZ and ATM Aperture
Configurable to ±1.9% or
100% of full scale
Motion
Band
Configurable to ±1 or ±3
grads; 1-second delay or no
delay
Calibration
Method
Software, with optional
five-point linearization
Serial Communications
Port 1
Full duplex 20 mA at 9600, 4800, 2400, 1200,
600, or 300 bps
Operator Interface
Display
6-digit LED display. 7-segment, .6 in (15
mm) digits
Annunciators
Center of zero, Gross, Net, Motion, lb/kg
Keyboard
21-key flat membrane panel with 0–9
numeric keys, ENT (Enter), CE (Clear Entry),
ZERO, GROSS/NET, TARE, TARE RECALL,
PRINT, lb/kg CONV, SP1, SP2, ON/OFF
Environmental
Operating Temperature
–10 to +40 °C (14 °F to 104 °F)
Enclosure
Enclosure Dimensions
9.0 in x 6.44 in x 4.0 in
23 cm x 16 cm x 10 cm
See Figure 6-1 on page 41
Rating/Material
NEMA 4X, stainless steel
Certifications and Approvals
NTEP
CoC Number
89-023A299-010
Accuracy Class
III/III L
n
max
: 10 000
FM #0Z0AZ.AX
•
N
A
T
IO
NA
L CONFE
R
E
N
C
E
•
O
N
W
E
I G
H
T S
A N D M
E
A
S
U
R
E
S