Rice Lake Condec UMC600IS User Manual
Page 26
Configuration
23
3.3.4
Option 4 – Auto Shutoff Mode
The auto shutoff mode can prolong battery life for
applications using the battery input power to the
indicator.
Option 4 allows the indicator to be configured to shut
off automatically when idle for a specified time (1–9
minutes). Parameter 4.2 can be enabled to reset the
shutoff timer if motion is detected on the scale after
the timer is started.
Option 4 is not a “sleep mode”; once the indicator
shuts off, it must be turned on again. With Option 4
enabled, the on/off switch becomes active (see
Figure 3-12) and can be used to restart the unit.
NOTES:
•
Option 4 requires hardware setup inside the
indicator enclosure and must be enabled at the
factory.
•
Option 3 (time and date) must be enabled and
set to use Option 4.
Prompts for auto shutoff mode (OP.4) are shown in
Table 3-13.
Figure 3-12. On/Off Switch for Option 4
3.3.5
Option 6 – Five-Point Linear Calibration
There are five calibration points that can be entered
sequentially. Calibrations using fewer than five points
will linearize the curve up to the last data point.
E n a b l i n g O p t i o n 6 p l a c e s t h e i n d i c a t o r i n a
linearization calibration when the unit is in the
calibration mode (SW1-1 closed on front panel DIP
switch). Use the five-point linearization procedure
outlined in Section 4.3 on page 30 to perform a scale
calibration when Option 6 is enabled.
The five-point linearization calibration (OP.6) is
shown in Table 3-14.
Prompt Display
Interpretation
Auto Shutoff Mode
OP.4
oFF
Off: Auto shutoff mode disabled
OP.4
on
On: Auto shutoff mode enabled
Shutoff timer value
4.1
n
Set number of minutes, 1–9, before
shutoff
Motion detection
4.2
on
On: Shutoff timer is reset if motion is
detected before timer expires
4.2
oFF
Off: Indicator always shuts down when
shutoff timer expires
Table 3-13. Option 4 Configuration Selections
1
6
2
7
3
8
4
9
5
0
CE
ENT
TARE
RECALL
ZERO
NET
GROSS
TARE
lb/kg
CONV
1 SET
POINT
2 SET
POINT
CAPACITY
600 x 0.1
ZERO
NET
GROSS
lb
kg
MOTION
ON/OFF switch
Prompt
Display
Interpretation
Notes
Five-point linearization
OP.6
oFF
Off
—
OP.6
on
On
Enter up to five linearization
points