Brocade DCX 8510-8 Backbone Hardware Reference Manual User Manual
Page 132

You can calculate your power requirements by combining the power draws for the various blades and
fan units in your configuration. While you may use fewer ports in a given blade, it is always safer to
use the power requirement of a fully populated blade.
Power demands per component
TABLE 23
Blade or fan
units
Maximum Power
Draw (Watts)
Type of Blade Ports per blade
Number of
blades
permitted in
chassis
Total ports per
chassis
CP8
40
Control blade
NA
2
NA
CR16-8
240
Core blade
16 64-Gbps QSFP
ports
2
32 quad ports
(128 ports)
FC8-32E
140
Port blade
32 8-Gbps SFP+
up to 8
256
FC8-48E
160.4
Port blade
48 8-Gbps SFP+
up to 8
384
FC8-64
126.4
Port blade
64 8-Gbps SFP+
up to 8
512
FC16-32
140
Port blade
32 16-Gbps SFP+
- can use 8-Gbps
SFP+
up to 8
256
FC16-48
160.4
Port blade
48 16-Gbps SFP+
- can use 8-Gbps
SFP+
up to 8
384
FC16-64
134
Port blade
16 QSFPs (4 16-
Gbps ports per
QSFP)
up to 8
512
FCOE10-24
250
Application
blade
24 10-Gbps SFP+
Fibre Channel
over Ethernet
up to 1 (slot 1
only)
24
FS8-18
235
Encryption
blade
16 8-Gbps SFP+
up to 4
64
FX8-24
250
Extension
blade
12 8-Gbps SFP+,
10 1-Gbps
Ethernet, 2 10-
Gbps Ethernet
up to 4
48 8-Gbps, 40 1-
Gbps Ethernet, 8
10-Gbps
Ethernet
Fan unit
90
NA
NA
3 fans per
chassis
NA
Power supply redundancy is key to your installation, so any demand must be met with twice the
capacity. Refer to the following table for power supply requirements for specific demand ranges.
Specifications
132
Brocade DCX 8510-8 Backbone Hardware Reference Manual
53-1002180-07