Environmental requirements, General specifications, Environmental requirements general specifications – Brocade 6510 Hardware Reference Manual User Manual
Page 45

Environmental requirements
The following table lists the acceptable environmental ranges for both operating and nonoperating (such
as during transportation or storage) conditions.
Environmental requirements
TABLE 8
Condition
Acceptable during operation
Acceptable During Non-Operation
Ambient
Temperature
0º to 40º C (32º to 104º F)
-25º to 70º C (-13º to 158º F)
Humidity
10% to 85% RH non-condensing, at 40º C (104º F)
10% to 90% RH non-condensing, at
70º C (158º F)
Altitude
0 to 3 km (9,842 feet) above sea level
0 to 12 km (39,370 feet) above sea
level
Shock
20 G, 6 ms, half-sine wave
33 G, 11 ms, half-sine wave, 3/eg
Axis
Vibration
0.5 G sine, 0.4 gms random, 5-500 Hz
2.0 G sine, 1.1 gms random, 5-500
Hz
Air flow
Maximum - 71.36 cmh (42 cfm)
Nominal - 59.47 cmh (35 cfm)
NOTE: Airflow can be Forward or Reverse
depending on purchased option
NA
Heat dissipation
338 BTU/hr (32 port configuration)375 BTU/hr (48
port configuration)
NA
General specifications
The following table lists the general specifications for the Brocade 6510.
General specifications
TABLE 9
Specification
Description
Configurable port types
F_Port, E_Port, M_Port, EX_Port, and D_Port
System architecture
Nonblocking shared-memory switch
System processor
PowerPC 440EPx @ 667 MHz
ANSI Fibre Channel protocol
FC-PH ( Fibre Channel Physical and Signalling Interface standard)
Environmental requirements
Brocade 6510 Hardware Reference Manual
45
53-1002174-08