Communication (ethernet) > sntp client – Yokogawa Button Operated DX2000 User Manual
Page 93
91
Installation and W
iring
Recommended Replacement
Periods for W
orn Parts
Setup Items and
Default V
alues
IM 04L42B01-02E
Setup Items and Default Values
Communication (Ethernet) > E-Mail > System settings
Setup Item
Selectable Range or Selections
Default Value
Setting
Recipient 1
Recipient 2
On/Off
On/Off
Off
Off
Include source URL
Subject
Header 1
Header 2
On/Off
32 characters or less
64 characters or less
64 characters or less
Off
System_warning
–
–
Communication (Ethernet) > E-Mail > Report settings
Setup Item
Selectable Range or Selections
Default Value
Setting
Recipient 1
Recipient 2
On/Off
On/Off
Off
Off
Include source URL
Subject
Header 1
Header 2
On/Off
32 characters or less
64 characters or less
64 characters or less
Off
Report_data
–
–
Communication (Ethernet) > FTP client > FTP transfer file
Setup Item
Selectable Range or Selections
Default Value
Setting
Without /AS1
FTP transfer file > Disp&Event data
FTP transfer file > Report
FTP transfer file > Snapshot
On/Off
On/Off
On/Off
Off
Off
Off
Transfer wait time > Disp&Event data
*2
Transfer wait time > Report
*2
0 to 120 min
0 to 120 min
0
0
With /AS1
*3
FTP transfer file > Disp&Event data
On/Off
Off
FTP transfer file > Report
On/Off
Off
FTP transfer file > Snapshot
On/Off
Off
FTP transfer file > Setting
On/Off
Off
The Transfer wait time items are the same as on a DX without the /AS1 option.
Communication (Ethernet) > FTP client > FTP connection
Setup Item
Selectable Range or Selections
Default Value
Setting
FTP connection
Primary/Secondary
Primary
FTP server name
64 characters or less
–
Port number
0 to 65535
21
Login name
32 characters or less
–
Password
32 characters or less
******...***
Account
32 characters or less
–
PASV mode
On/Off
Off
Initial path
64 characters or less
–
Communication (Ethernet) > SNTP client
Setup Item
Selectable Range or Selections
Default Value
Setting
SNTP client > Use/Not
Use/Not
Not
SNTP client > Server name
64 characters or less
–
SNTP client > Port number
0 to 65535
123
SNTP client > Access interval
Off/1h/8h/12h/24h
8h
SNTP client > Access reference time
00:00 to 23:59
00:00
SNTP client > Access timeout
10s/30s/90s
30s
SNTP client > Time adjust on Start action On/Off
Off