Wa t l o w S e r i e s C

• 19 •

O r d e r i n g I n f o r m a t i o n

Ordering Information and Model Numbers

On-off controller, LED Display

C V

_ _ _ _

_ _ _ _

_ _ _ _

_

Set Point Type

V

Variable Set Point

Line Voltage and Output

B

120VÅ (ac), Switched DC Output

C

120VÅ (ac), 8 Amp Relay Output

D

230 to 240VÅ (ac), Switched DC Output

E

230 to 240VÅ (ac), 8 Amp Relay Output

F

24VÅ (ac), Switched DC Output

G

24VÅ (ac), 8 Amp Relay Output

Controller Package

1

Panel Mount, 1/8 DIN Square, Rotary Knob -Spade Terminals

2

DIN Rail Mount, Rotary Knob -Spade Terminals

5

Panel Mount, 1/8 DIN Square, Rotary Knob -Screw Terminals

6

DIN Rail Mount, Rotary Knob -Screw Terminals

A

NEMA 4X Panel Mount, Tactile Keys, Spade Terminals

B

DIN Rail Mount, Tactile Keys, Spade Terminals

C

NEMA 4X Panel Mount, Tactile Keys, Screw Terminals

D

DIN Rail Mount, Tactile Keys, Screw Terminals

Sensor and Sensor Operating Range

H

Type J -346 to 1900 Degrees F

J

Type J -210 to 1038 Degrees C

K

Type K -454 to 2500 Degrees F

L

Type K -270 to 1370 Degrees C

M

Type T -454 to 750 Degrees F

N

Type T -270 to 400 Degrees C

P

100

Ω RTD -328 to 1472 Degrees F

R

100

Ω RTD -200 to 800 Degrees C

S

Type E -328 to 1470 Degrees F

T

Type E -200 to 800 Degrees C

Control Mode

H

Heat

C

Cool

Low Set Point Range Limit *

XXXX

Low Set Point Operating Range Value**

High Set Point Range Limit *

XXXX

High Set Point Operating Range Value**

Overlay/Custom Options (A through D contain the Watlow Logo on the overlay; 1 through 4 do not have the Watlow Logo on the overlay)

A

Standard, displays set point only. Set point is adjustable from default display.

B

Displays set point, and set point is adjustable. Press Process Key to display process.

C

Displays set point. Press Push to Set Key, to allow set point to be adjusted.

D

Displays process. Press Push to Set Key, to allow set point to be adjusted.

1

Standard, displays set point only. Set point is adjustable from default display.

2

Displays set point, and set point is adjustable. Press Process Key to display process.

3

Displays set point. Press Push to Set Key, to allow set point to be adjusted.

4

Displays process. Press Push to Set Key, to allow set point to be adjusted.

*Note: Set point ranges must fall within the sensor operating range.

**Note: A (-) is used in the left digit of the operating range to indicate negative temperature values.