Output specifications (sink type) – Proface AGP3500 - 10.4 DIO HMI" User Manual
Page 3
3
Output Specifications (Sink type)
Output Circuit (Sink type)
• Since the output terminals are not electrically protected, an output line might be short-
circuited or a connection fault might damage the GP unit. Please install an applicable fuse to
prevent an overload in the circuit, if necessary.
Rated Voltage
DC 24V
Rated Voltage Range
DC 20.4V to DC 28.8V
Output Method
Sink Output
Maximum Load Voltage
0.2A /point, 0.4A /common
Output Voltage Drop
1.5V or less
Output Delay
Time
OFF to ON
1ms or less
ON to OFF
1ms or less
Voltage Leakage (when OFF)
0.1mA or less
Clamp Voltage
39V ± 1V
Type of Output
Transistor Output
Common Lines
1
Common Design
2 points/1 common line
External Connection
12-pin connector (also used for Input)
Output Protection Type
Output is unprotected
Internal Fuse
1.5A, 125V DIP fuse (not replaceable)
Surge Control Circuit
Zener diode
Output Points
2
Output Signal Display
No LED indicators
Status Display Element
None
Isolation Method
Photocoupler Isolation
External Power Supply
DC 24V
L
L
+24V B1
0V A1
Internal Circuit
OUT1 A2
Internal Circuit
OUT0 B2
Fuse
1.5A
+
-
DC 24V
External Power
- AGP3400 - 7.5 DIO HMI" AGP3300 - 5.7 DIO HMI" AGP3600 - 12.1 FLEX Network HMIs" AGP3500 - 10.4 FLEX Network HMI" AGP3400 - 7.5 FLEX Network HMI" AGP3600 - 12.1 CANopen HMI" AGP3500 - 10.4 CANopen HMI" AGP3400 - 7.5 CANOpen HMI" AGP3300 - 5.7 CANopen HMI" AGP3300H - 5.7 Handheld HMIs" AGP3750 - 15 Multi-Media HMI" AGP3650 - 12.1 Multi-Media HMIs" AGP3550 - 10.4 Multi-Media HMIs" AGP3450 - 7.5 Multi-Media HMI" AGP3360 - 5.7 Multi-Media HMI" AST3300 - 5.7 Basic HMI" AST3200 - 3.8 Basic HMI" AGP3600 - 12.1 Standard HMIs" AGP3500 - 10.4 Standard HMIs" AGP3400 - 7.5 Standard HMI" AGP3300 - 5.7 Standard HMI" AGP3200 - 3.8 Standard HMI"