Proface AGP3500 - 10.4 DIO HMI" User Manual
Page 6
6
COM2
• Always connect close to the GP unit's COM port when terminating with the
termination pins (TRMRX/TRMTX).
Recommended Cable
Connector
XM2A-0901
Recommended Jack Screw
XM2Z-0073
Recommended Cable Cover XM2S-0913
Fitting fastener
#4-40 (UNC)
Pin #
RS422/RS485
Signal Name
Meaning
1
TRMRX
Termination (Receiver side: 100
Ω)
2
RDA
Receive Data A(+)
3
SDA
Send Data A(+)
4
RS(RTS)
Request for Send
5
SG
Signal Ground
6
VCC
+5V ±5% Output 0.25A
*1
*1 The VCC output for Pin #6 is not protected against overcurrent. To prevent damage or unit
malfunctions, use only the rated current.
7
RDB
Receive Data B(-)
8
SDB
Send Data B(-)
9
TRMTX
Termination (Receiver side: 100
Ω)
Shell
FG
Frame Ground (Common with SG)
This manual is related to the following products:
- AGP3400 - 7.5 DIO HMI" AGP3300 - 5.7 DIO HMI" AGP3600 - 12.1 FLEX Network HMIs" AGP3500 - 10.4 FLEX Network HMI" AGP3400 - 7.5 FLEX Network HMI" AGP3600 - 12.1 CANopen HMI" AGP3500 - 10.4 CANopen HMI" AGP3400 - 7.5 CANOpen HMI" AGP3300 - 5.7 CANopen HMI" AGP3300H - 5.7 Handheld HMIs" AGP3750 - 15 Multi-Media HMI" AGP3650 - 12.1 Multi-Media HMIs" AGP3550 - 10.4 Multi-Media HMIs" AGP3450 - 7.5 Multi-Media HMI" AGP3360 - 5.7 Multi-Media HMI" AST3300 - 5.7 Basic HMI" AST3200 - 3.8 Basic HMI" AGP3600 - 12.1 Standard HMIs" AGP3500 - 10.4 Standard HMIs" AGP3400 - 7.5 Standard HMI" AGP3300 - 5.7 Standard HMI" AGP3200 - 3.8 Standard HMI"