The Delay box is used to select the time that must elapse since the last keypress on the OIT or
the last message received from the PLC before the screen saver is enacted. The range is from
5-60 minutes. The Text box is used to enter the single line screen that will scroll across the
OIT display when the screen saver is active. Note that the extended characters can also be
used here. When finished, click on the Done button to go back to the prior screen.
The Insert Special Character and Clear Current Screen buttons from the main tool bar are
repeated here for convenience.
OIT Supervisor Editor
This feature is selected from within the Configuration Editor and the following screen appears:
The OIT Supervisor Editor allows the enabling or disabling of certain features on the OIT.
General Group Box:
When the Enable OIT Limit Warnings check box is checked, the OIT displays the high or
low limit for the Register Monitor whose value is being entered out-of-range. Otherwise, the
OIT displays a message indicating that the value being entered is out-of-range.
Current Message Register Group Box:
When the Enable ? check box is checked, the OIT will place the number of the last message
currently displayed on the OIT into the Current Message Register. This register can then be
used by the PLC to determine which message is shown on the OIT.
MAPware 100 User's Guide
23
1010-0089, REV00