OPERATION (USER MODE)
B-16
GAS SET-UP SCREEN
OVERVIEW
On this screen, the user selects the gas mixture and
gasflowrate.SeeFigureB.28.Thecorrectgasmix-
tureandflowratemustbeenteredaccordingtothetol-
eranceeditor.Ifacceptablevaluesarenotentered,this
will be indicated on a later screen and the user may
have to go back and change the selection on this
screen.
Toselectthegasmixture,touchthedesiredicon.The
available gas mixtures are shown on the gas set-up
screenbelow.
To select the gas flow rate, touch the desired arrow
iconorthegasflowmeter.
MENU
Selecting Logout takes the user back to the login
screen,withtheuser’snameremoved.
BACk
SelectingBack takestheusertothepreviousscreen.
WELD MACHINE SETTINGS
SCREEN
OVERVIEW
Theusermustentertheproperweldingprocedureand
process settings, including wire feed speed, amper-
age,voltage,polarityandtrimwhereapplicable.See
FigureB.29.Asinthegassetupscreen,theusermust
entervalueswithintheacceptablerangeasgoverned
bythetoleranceeditor.Ifnot,theywillbenotifiedby
theincorrectweldsettingscreenwhenthegreencheck
settingsiconisselected.SeeFigures B.30 and B.31.
Theuserchangesthewirefeedspeedoramperageby
rotating the virtual wire feed speed/amperage dial.
Thedisplayabovethedialindicatesthesetting.
The user changes the voltage by rotating the voltage
dial.Thedisplayabovethedialindicatesthesetting.
Someprocessesmaynotallowtheusertopre-setthe
voltage,inwhichcasethedisplaywillbeblank.
POLARITY SELECTOR
Change the polarity by rotating the virtual polarity
selectoricon.Theusercanselectthefollowing:
•AC
•DC+
•DC-
If default tolerances are being used, see the
Default Weld Process Settings included in this
manual.
Once the user has set the welding parameters, they
shouldselectthegreenchecksettingsicon.Iftheuser
hasenteredanysettingsoutsidetheacceptablerange
specified by the settings in the tolerance editor, the
incorrectweldsettingscreenwillappear.
VRTEX
®
MOBILE
FIGURE B.28 – GAS SET-UP SCREEN
FIGURE B.29 – WELD MACHINE
SETTING SCREEN