E-4

TROUBLESHOOTING

E-4

POWER WAVE

®

AC/DC 1000

®

SD

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

BASIC MACHINE PROBLEMS

Major physical or electrical damage
is evident when the sheet metal
covers are removed.

Input fuses keep blowing

Machine will not power up (no
lights)

None

1.

Improperly sized input fuses.

2.

Improper Weld Procedure
requiring output levels in
excess of machine rating.

3.

Major physical or electrical
damage is evident when the
sheet metal covers are
removed.

1.

No Input Power.

2.

Fuse F1 (in reconnect area)
may have blown.

3.

Circuit breaker CB1 (on the
control panel) may have
tripped.

4.

Improper input voltage selec-
tion (multiple input voltage
machines only).

1. Contact your local authorized

Lincoln Electric Field Service
facility for technical assis-
tance.

1.

Make sure fuses are properly
sized. See installation section
of this manual for recom-
mended sizes.

2.

Reduce output current, duty
cycle, or both.

3.

Contact your local authorized
Lincoln Electric Field Service
facility for technical assis-
tance.

1.

Make sure input supply dis-
connect has been turned ON.
Check input fuses. Make cer-
tain that the Power Switch
(SW1) on the power source is
in the “ON” position.

2.

Power Down and replace the
fuse.

3.

Power Down and reset CB1.

4.

Power down, check input volt-
age reconnect according to
diagram on reconnect cover.