Vanguard DMOM‐600 User Manual
Page 13
![background image](/manuals/354131/13/background.png)
REV 2 Auto‐Ohm 200 S3 / DMOM‐200 S3 / DMOM‐600 USER’S MANUAL
9
1.5
Auto-Ohm 200 S3 Technical Specifications
Table 1. Auto-Ohm 200 S3 Technical Specifications
TYPE
Portable Micro-Ohmmeter
PHYSICAL SPECIFICATIONS
17" W x 7" H x 13" D (43.2cm x 17.8cm x 33cm); Weight: 16.8 lbs (7.6 Kg)
INPUT POWER 100-240 Vac, 14A, 50/60Hz
RESISTANCE READING
RANGE
1 micro-ohm to 10 milliohms at 200 A (0.1 micro-ohm resolution)
1 micro-ohm to 5 ohms at 1A
ACCURACY
1A to 4.99A: 1% ±10 micro-ohms
5A to 9.99A: 1% ±2 micro-ohms
10A to 200A: 1% ±1 micro-ohm
TEST CURRENT RANGE
1 Ampere to 200 Amperes (selectable in 1A steps);
Thermally protected DC power supply
DISPLAY
Backlit LCD (128 x 64 pixels), viewable in direct sunlight and low light levels
KEYPAD
Rugged, 44key "QWERTY" membrane keypad
INTERNAL TEST RECORD
STORAGE
128 test records. Each record can contain up to 64 readings
EXTERNAL TEST RECORD
STORAGE
Up to 999 test records on external USB Flash drive.
COMPUTER INTERFACE
RS-232C
PC SOFTWARE
Windows XP/Vista/7 Analysis Software (included with purchase)
SAFETY Designed to meet IEC 61010 (1995), UL 61010a, and CASC22.2 standards
ENVIRONMENT Operating: 10˚C to 50˚C (15˚F to +122˚F)
Storage: 30˚C to 70˚C (22˚F to +158˚F)
HUMIDITY (MAX) 90% RH @ 40˚ C (104˚ F) non-condensing
ALTITUDE (MAX) 2000m (6562 ft) to full safety specifications
CABLES 30 ft (9.1 m), #1 AWG test cables, power cord, ground cable
OPTIONS Shipping case, 15 ft test cables, C-Clamp set, Hand Spike Set, Dual Ground
option
WARRANTY One year on parts and labor
NOTE
The above specifications are valid at nominal operating voltage and at a
temperature of 25C (77F). Specifications may change without prior notice.