Troubleshooting – Tracer TP-9363 PRO-Chek CG AM08045-4 User Manual
Page 9
9
Troubleshooting
WARNING
Substitution of components may impair intrinsic safety.
Except for the batteries and the sensor, the internal parts of the
PRO-Chek CG Combustible Gas Leak Detector are not user serviceable.
If you experience a problem with your PRO-Chek CG, follow the steps in
the troubleshooting guide below to determine how to remedy your problem.
If you cannot remedy the problem, contact the supplier for warranty
evaluation and instructions.
PROBLEM
POSSIBLE CAUSE
REMEDY
The PRO-Chek CG will
not power up.
Batteries are worn out.
Replace batteries.
Batteries are improperly
installed.
Refer to Figure 1 for
proper installation.
Poor sensitivity. Unit
powers up, but has a
difficult time detecting
combustible gas.
Sensitivity setting is
too low.
Increase sensitivity by
dragging finger upward on
touch pad.
Sensor is worn out and
needs to be replaced.
Replace sensor.
Alarm sounds
continuously, even after
a couple minutes of
warm-up.
The sensor is not installed
properly, is missing or is
worn out.
The sensor leads must
be straight and inserted
in the holes at the base
of the sensor socket.
Or, the orientation tab is
not properly aligned in
the probe tip. Refer to
Figure 2.
Sensor is worn out and
needs to be replaced.
Replace sensor.