beautypg.com

Description, Table 1 – general performance specifications, Figure 1 – siac layout – KB Electronics KBAC-48 User Manual

Page 27

background image

27

APPENDIX A – OPTIONAL SIAC SIGNAL ISOLATOR (PART NO. 9600)

See SIAC Installation Instructions (Part No. A40149) for details and connections.

Description

The SIAC provides an isolated interface between non-isolated signal sources and the drive. It is used with

the KBAC Series drives to isolate, amplify, and condition DC voltage and current signals from any source

(tach-generators, transducers, PLCs, and potentiometers). It also provides an isolated input to control

motor direction and an isolated +5 Volt power supply for transducer or potentiometer operation. All input

connections are isolated from the AC line and motor wiring. The SIAC installs easily in the KBAC with a snap-in

mounting base and is wired with a connector.

The main features of the SIAC include voltage or current signal inputs. Other features include a power on

LED, a barrier terminal block to facilitate wiring, multi-turn trimpots (SCALE (MAX), OFFSET), and a selectable

jumper for voltage or current signal input selection. An optional accessory for use with the SIAC and KBAC is

an Auto/Manual Switch (Part No. 9481) which selects a signal input from either the SIAC or the Main Speed

Potentiometer.

Table 1 – General Performance Specifications

Description

Specification

Factory Setting

Scale Trimpot (SCALE) Input Voltage Range (Volts DC)

0 to ±2.5 thru 0 to ±25

0 to ±5

Offset Trimpot (OFFSET) Range (% of MAX Trimpot Setting)

0 – ±50

0

Input Current Range (milliamps DC)

4 – 20

Forward and Reverse Input Switch Types

Dry Contact or Open Collector

+5V Power Supply Maximum Load Current Rating (milliamps DC)

25

Potentiometer Operation (kΩ)

5

Input/Output Linearity (%)

0.1

Thermal Drift (millivolts per °C)

0.4

Operating Temperature Range (°C / °F)

0 – 40 / 32 – 103

COM

SIG1

+5V

FWD REV

-5V COM

IND

PWR

CON1

J1

CUR

VO

LT

OFFSET

SCALE

VDC

(MAX)

TB1

TB1: Main Speed Potentiometer, Signal Input,
and Direction Switch connections.
J1: Sets the drive for operation with a voltage
or current input signal.

PWR LED: Provides indication that power is applied.
IND LED: Status Indicator (flashing green).
OFFSET: Signal Offset adjustment multi-turn trimpot.
SCALE (MAX): Input voltage adjustment multi-turn trimpot.
CON1: Used to connect the SIAC to the drive.

VDC: Factory use only.

PGM

J7

J7: Factory use only.

Figure 1 – SIAC Layout