beautypg.com

Table 3 – general performance specifications, Table 4 – electrical ratings – KB Electronics KBAC-48 User Manual

Page 10

background image

10

Table 3 – General Performance Specifications

Description

Specification

Factory Setting

115 Volt AC Line Input Voltage Operating Range (Volts AC)

115 (±15%)

208/230 Volt AC Line Input Voltage Operating Range (Volts AC)

208 (-15%) / 230 (+15%)

400/460 Volt AC Line Input Voltage Operating Range (Volts AC)

380 (-15%) – 460 (+15%)

Maximum Load (% Current Overload for 2 Minutes)

150

Carrier, Switching Frequency (kHz)

16, 8

Signal Following Input Voltage Range

1

(Volts DC)

0 – 5

Output Frequency Resolution (Bits, Hz)

10, .06

Minimum Speed Trimpot (MIN) Range (% Frequency Setting)

0 – 40

0

Maximum Speed Trimpot (MAX) Range (% Frequency Setting)

70 – 110

100

Acceleration Trimpot (ACCEL) and Deceleration Trimpot (DECEL) Range (Seconds)

.3 – 20

1.5

Boost Trimpot (BOOST) Range (Volts/Hz)

0 – 30

5

Slip Compensation Trimpot (COMP) Range at Drive Rating (Volts/Hz)

0 – 3

1.5

Current Limit Trimpot (CL) Range (% Full Load)

40 – 200

160

Jog Trimpot (JOG) Range (% Frequency Setting)

0 – 100

35

Motor Frequency Setting (Hz) (Jumper J5)

50, 60

60

Output Frequency Multiplier (1X, 2X) (Jumper J4)

2

1, 2

1

Minimum Operating Frequency at Motor (Hz)

1

Speed Range (Ratio)

60:1

Speed Regulation (30:1 Speed Range, 0 – Full Load) (% Base Speed)

3

2.5

Overload Protector Trip Time for Stalled Motor (Seconds)

6

Undervoltage/Overvoltage Trip Points for 115 Volt AC Line Input (± 5%) (Volts AC)4

76 – 141

Undervoltage/Overvoltage Trip Points for 208/230 Volt AC Line Input (± 5%) (Volts AC)

4

151 – 282

Undervoltage/Overvoltage Trip Points for 400/460 Volt AC Line Input (± 5%) (Volts AC)

4

302 – 567

Run/Fault Relay Output Contact Rating (Amps at 30 Volts DC, 125 Volts AC, 250 Volts AC)

1, 0.5, 0.25

Operating Temperature Range (°C / °F)

5

0 – 40 / 32 – 104

Operating Humidity Range (% Relative, Non-Condensing)

0 – 95

Storage Temperature Range (°C / °F)

-2.5 – +85 / -13 – +185

Notes: 1. Requires an isolated signal. If a non-isolated signal is used, or if using 0 to ±2.5 thru 0 to ±25 Volts DC, or 4 – 20 mA DC signal input, install the SIAC
Signal Isolator (Part No. 9600). 2. Allows the motor to operate up to two times the rated RPM. Constant horsepower will result when operating the drive in
the “X2” mode above the motor rated frequency. 3. Dependent on motor performance. 4. Do not operate the drive outside the specified AC line input voltage
operating range. 5. See Table 4 below.

Table 4 – Electrical Ratings

Model No.

Part No.

Max. HP

AC Line

Voltage

(50/60 Hz)

Phase

(Ø)

Max.

AC Line

Current

(Amps AC)

Fuse or

Circuit

Breaker

Rating

(Amps)

Voltage

Range

(Volts AC)

Max. Load

Current

(Amps/Phase)

Motor

Horsepower

Selection

2

(Jumper J2)

Net Wt.

Gray White

1

HP kW

lbs kg

KBAC-24D

9987 9988 1 .75

115

1

8.1

20

0 - 208/230

3.6

1 3/4 1/2 1/4 1/8 5.9 2.7

208/230

15

KBAC-27D

9520 9521

11/2 1.13

115

1

22

25

0 - 208/230

5.5

11/2

3

1 3/4 1/2 10.3 4.7

2 1.5 208/230

16.7

20

6.7

2

3

A B C D E

KBAC-29 (1P)

4

10001 10002 3 2.25 208/230

1

20.5

25

0 - 208/230

9

3

2 11/2 1 3/4

10.3 4.7

KBAC-29

9528 9529

2 1.5

208/230

1

20.5

20

0 - 208/230

6.7

2

5

11/2 1 3/4

3 2.25

3

11.7

15

9

3

5

KBAC-45

6

9530 9531 3 2.25 400/460

3

7.2

10

0 – 400/460

5.5

3 2 11/2 1 3/4

KBAC-48

6

9540 9541 5 3.75 400/460

3

11

15

0 – 400/460

8.3

5

3

2 11/2 1

Notes: 1. White FDA approved finish. 2. Bold indicates factory setting. Jumper J2 on Model KBAC-24D is labeled “1”, “3/4”, “1/2”, “1/4”, “1/8” (factory set to the
“1” position). Jumper J2 on Model KBAC-27D is labeled “2”, “11⁄2”, “1”, “3/4”, “1/2” (factory set to the “11⁄2” position). Jumper J2 on Models KBAC-29, 45, 48 is
labeled “A”, “B”, “C”, “D”, “E” (factory set according to the table). 3. Model KBAC-27D is rated 11⁄2 HP maximum with 115 Volt AC line input and 2 HP maximum
with 208/230 Volt AC line input. 4. Model KBAC-29 (1P) is rated 9 Amps at 35 °C / 95 °F and derated to 8.3 Amps at 40 °C / 104 °F. For ambient temperatures
above 40 °C / 104 °F, the drive is derated 2.5% per °C. 5. Model KBAC-29 is rated 2 HP maximum with single-phase AC line input and 3 HP maximum with
3-phase AC line input. 6. Models KBAC-45, 48 are rated 0 – 400 Volts AC for 50 Hz motor operation and 0 – 460 Volts AC for 60 Hz motor operation.

This manual is related to the following products: