3. Connecting with the Controller

25

3. Connecting with the Controller

For the controller, only the dedicated controller manufactured by our company can be used.

Using other controllers may cause a problem such as burning the product, ignition or generating heat.

Use the dedicated cable enclosed in the package when connecting the actuator and the controller.

[Connecting with XSEL-J/K Controller]

Dedicated cable

(Connect actuator with the dedicated controller)

r = 51mm or mere (Movable Use)

r = 34mm or mere (Fixed Use)

Dedicated controller

XSEL-J/K

x

Motor Cable CB-X-MA***

x

Encoder Cable CB-X-PA***

x

Limit Switch Cable CB-X-LC***

*** indicates the cable length.

Up to 30m can be specified.

Example) 080 = 8 m

[Connecting with XSEL-P/Q, SSEL, SCON Controller]

Dedicated cable

(Connect actuator with the dedicated controller)

r = 58mm or mere (Movable Use)

r = 38mm or mere (Fixed Use)

Dedicated controller

XSEL-P/Q, SSEL, SCON

x

Motor Cable CB-X-MA***

x

Encoder Cable with LS CB-X1-PLA***

*** indicates the cable length.

Up to 30m can be specified.

Example) 080 = 8 m