Table 3-7 Dual Speed Hoist (w/VFD) Speed/Frequency Change Procedure



 Each dual speed hoist model has a range of available speeds/frequencies (upper and lower limits). Any

value outside the range listed in Table 3-6 for your specific hoist is strictly prohibited.

 Speeds must be set such as Low [d1-01] and High [d1-02].

After parameters are changed, a “no load” operational check must be performed.

Operational Step

VFD Display

1. Energize the hoist.

2. Press

until the “Setup Mode” screen is displayed (blinking).

3. Press

to display the parameter setting screen (blinking).

4. Press

or

until the desired parameter is displayed (blinking).

(Low Speed: d1-01, High Speed: d1-02)

5. When you press

, the current setting value is displayed (digit selected blinks).

(Example Value: 9 Hz)

6. Press

to move the blinking digit to the desired digit.

(Example Value: 9 blinks)

7. Press

or

until the desired setting is displayed and press

.

(Example Value: 8 Hz)

8. Press

to confirm the new setting.

9. The display will automatically return to the parameter screen (blinking).

(As in Step 4.)

10. Press

until the diplay returns to the initial screen.