3.6.1



To avoid a shock hazard, DO NOT perform ANY mechanical or electrical

maintenance on the dual speed ( VFD control) trolley or hoist within 5 minutes of de-energizing
(disconnecting) the trolley or hoist. This time allows the internal VFD capacitor to safely discharge.

3.6.2



Do Not remove power to the dual speed (VFD control) hoist or trolley during

operation.

3.6.3

All dual speed hoists are equiped with a VFD. The VFD is used to control the high and low lifting
speeds. The speeds come preset from the factory (Table 3-6). Speed (frequency) can be customized.
Refer to Section 3.6.10 for hoist specific speed ranges and instructions.

3.6.4

The VFD is controled by a Keypad/Display Interface. Refer to Figure 3-8 for Keypad/Display Interface
functions and descriptions.

Figure 3-8 VFD Keypad/Display Interface

3.6.5

When power is supplied to the hoist the VFD LED operator display will illuminate as shown Table 3-2.

Table 3-2 LED Operator Display