Harrington Hoists and Cranes (N)ER Hoist - ((N)ER2) User Manual
Page 21
21
3.6.9 The Run Lamp display provides hoist
“RUN” status. Table 3-5 shows the various “RUN” displays.
Table 3-5 Run Lamp
3.6.10 All of the hoists have speed/frequency ranges that can be customized to a specific application. Refer
to Table 3-6 for specific hoist speed/frequency ranges. To set custom speeds for an application, follow
the procedure listed in Table 3-7.
Table 3-6 VFD Speed & Frequency Ranges
Product Code
Hoist Speed (ft/min)
VFD Frequency (Hz)
Range*
Low
High
NER2
ER2
Low (d1-01)
High (d1-02)
Low (d1-01)
High (d1-02)
230V
460V
230V
460V
230V
460V
230V
460V
(N)ER2001HD
Low
4.5
55
3.2
3.3
57.0
57.0
4.9
3.3
57.5
57.0
Std
9.0
55
8.3
8.2
57.0
57.0
9.7
7.8
57.5
57.0
(N)ER2003SD
Low
3.0
36
3.2
3.3
57.0
57.0
4.9
3.3
57.5
57.0
Std
6.0
36
8.3
8.2
57.0
57.0
9.7
7.8
57.5
57.0
(N)ER2003HD
Low
4.3
53
2.6
2.5
53.5
54.0
2.8
2.5
55.0
54.0
Std
9.0
53
7.3
7.3
53.5
54.0
8.0
7.2
55.0
54.0
(N)ER2005LD
Low
1.2
15
3.2
3.3
57.0
57.0
4.9
3.3
57.5
57.0
Std
2.5
15
8.3
8.2
57.0
57.0
9.7
7.8
57.5
57.0
(N)ER2005SD
Low
2.3
29
2.6
2.5
53.5
54.0
2.8
2.5
55.0
54.0
Std
5.0
29
7.3
7.3
53.5
54.0
8.0
7.2
55.0
54.0
(N)ER2010LD
Low
1.1
14
2.6
2.5
53.5
54.0
2.8
2.5
55.0
54.0
Std
2.5
14
7.3
7.3
53.5
54.0
8.0
7.2
55.0
54.0
(N)ER2010SD
Low
2.2
28
2.3
2.1
53.0
53.5
2.7
3.0
53.0
53.5
Std
4.5
28
7.3
7.0
53.0
53.5
8.2
7.5
53.0
53.5
(N)ER2015SD
Low
1.4
18
2.3
2.1
53.0
53.5
2.7
3.0
53.0
53.5
Std
3.0
18
7.3
7.0
53.0
53.5
8.2
7.5
53.0
53.5
(N)ER2020CD
Low
0.5
7.0
2.6
2.5
53.5
54.0
2.8
2.5
55.0
54.0
Std
1.0
7.0
7.3
7.3
53.5
54.0
8.0
7.2
55.0
54.0
(N)ER2020LD
Low
1.0
14.0
2.3
2.1
53.0
53.5
2.7
3.0
53.0
53.5
Std
2.5
14.0
7.3
7.0
53.0
53.5
8.2
7.5
53.0
53.5
(N)ER2020SD
Low
2.2
28
2.6
3.0
54.0
55.0
2.8
3.0
52.0
55.0
Std
4.5
28
7.9
7.7
54.0
55.0
8.0
7.7
52.0
55.0
(N)ER2025SD
Low
1.8
22
2.6
3.0
54.0
55.0
2.8
3.0
52.0
55.0
Std
3.5
22
7.9
7.7
54.0
55.0
8.0
7.7
52.0
55.0
(N)ER2030LD
Low
TBD
TBD
TBD
TBD
TBD
TBD
TBD
TBD
TBD
TBD
Std
TBD
TBD
TBD
TBD
TBD
TBD
TBD
TBD
TBD
TBD
(N)ER2030CD
Low
1.4
17
2.6
3.0
54.0
55.0
2.8
3.0
52.0
55.0
Std
3.0
17
7.9
7.7
54.0
55.0
8.0
7.7
52.0
55.0
(N)ER2050LD
Low
0.9
11
2.6
3.0
54.0
55.0
2.8
3.0
52.0
55.0
Std
2
11
7.9
7.7
54.0
55.0
8.0
7.7
52.0
55.0
*Low = The minimum and maximum speed/frequency range (12:1 ratio).