Gilderfluke&Co old Smart Brick Manual User Manual
Page 72

¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥
ÒaÓ
Enter Track Number:
This command is used to tell the Brick Brain which addresses it should respond to from the serial com-
mands. No two Brick Brains or Digital Audio Repeater Cards on the same serial network can have the
same address assigned to them. When loaded with the default configuration, the address assigned to a
card is 00. If more than one Brick Brain or Digital Audio Repeater card is used in the system, they should
be plugged in one at a time to have their addresses changed. Once changed, each card can stay on
line.
The Rack Smart Brick Brain will show the current address, baud rate and parity on its display when it
first boots up.
¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥
ÒbÓ
Baud Rate:
All cards in the system must be set to the same baud rate. The default speed is 9600 baud. This
command doesn't take effect until you enter the eXit command. The serial port on each Brick Brain can
support any of the following baud rates:
1)
110
2)
150
3)
300
4)
600
5)
1200
6)
2400
7)
4800
8) 9600
(default value)
9)
19,200 (not exact)
10) 48,000
11) 144,000
The Rack Smart Brick Brain will show the current address, baud rate and parity on its display when it
first boots up.
¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥
ÒcÓ
Odd Parity Toggle:
This toggle enables the ODD PARITY data check on the serial port for this Brick Brain. Parity is a
method of confirming that the data sent to the audio system arrives intact. Any data that gets jumbled is
ignored. If ODD PARITY is enabled, it must be enabled on all the cards in the system as well as on your
computer or terminal. The default value for this command is off. This command doesn't take effect until
you enter the eXit command.
To indicate if parity is enabled, the Rack Smart Brick Brain will show a ÔpÕ or ÔnÕ after the baud rate
code on its display when it first boots up.
¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥
ÒdÓ
VT-52 Mode:
When this toggle is enabled, the Rack Smart Brick Brain will use special escape sequences to clear
the current line (
Analog Smart Brick has to redraw the entire screen to change any value, so it can save a good deal of
screen redraw time if you have a compatible display.
G
ILDERFLUKE
& C
O
.¥ 205 S. F
LOWER
S
T
.¥ B
URBANK
, CA 91502 ¥ 818/840-9484 ¥ 800/776-5972 ¥
FAX
818/840-9485
62 of 134