S
WITCH
#5:
F
RAME
R
ATE
:
S
WITCH
#6:
F
RAME
R
ATE
:
These two switches are used to select the frame rate being used by the MiniBrain. They are
used as follows:
Switch #4
Switch #5
Switch #6
Frame rate
OFF or ON
OFF
OFF
15 FPS
OFF or ON
ON
OFF
16 FPS
OFF or ON
OFF
ON
30 FPS
OFF
ON
ON
External Clock through Blue Input
ON
ON
ON
32 FPS
The 32 FPS frame rate is unavailable unless the card is using the Blue input for selecting a sec-
ond show. When external clock is selected, the frames displayed on a heads up display will carry
into the seconds every thirty frames, no matter what rate the frames are actually arriving at the
MiniBrain.
S
WITCH
#7:
S
TOP
O
N
G
REEN
O
PENING
:
When this switch is turned on, the MiniBrain will stop when the Green input is opened. This
switch is used when you would like the show to run AS LONG as the Green input is closed. The
MiniBrain will start playing when the Green input is activated, and stop when the Green input is
deactivated.
S
WITCH
#8:
R
UN
C
ONTINUOUS
:
This switch works in parallel with the Green input. When it is ON, the MiniBrain will start playing.
At the end of a show, the MiniBrain will reset back to the first frame and continue playing from the
beginning of the show. This switch can be used to start a show playing, or if it is left ON the
MiniBrain will start playing as soon as power is applied and will loop at the end of the show. Note
that when this switch is left ON, the Green input is disabled.
G
ILDERFLUKE
& C
O
.¥ 205 S. F
LOWER
S
T
.¥ B
URBANK
, CA 91502 ¥ 818/840-9484 ¥ 800/776-5972 ¥
FAX
818/840-9485