Off on, Important: switch #4 must be left in off position – Robertshaw Deluxe Programmable User Manual

Page 18

background image

OUTPUT TERMINAL FUNCTIONS – 300-226

18

W1 ................Auxiliary heat is energized as second stage

heating or emergency heat

Y1 .................Compressor is energized with a call for

heating or cooling

G...................Fan is energized with a call for heating or

cooling or selected by pressing the FAN
button

R ...................Independent Switching Voltage**

24V ...............24 VAC hot from the equipment transformer

24V(c)...........24 VAC common from the equipment

transformer

LED 1...........Free lights for status or function indication
LED 2

RS2 ..............Use to connect outdoor temperature sensor
RS1

and/or indoor remote sensor options. Refer

RS+V

to the instructions included with the sensors.

O...................Energizes the reversing continuously in the

cooling mode.

B..................Energizes the reversing continuously in the

heating and off modes.

** Allows for DC operation required on some older

Lennox and McQuay units.

*Not used — must be OFF

Not used*

1

2

3

4 min. (on/of

f)

2 min. (on/of

f)

Unlocked

Locked

Standard

Add-on

LED #1 only

LED #1 with filter symbol

LED #2 only

LED #2 with fault symbol

4

5

6

300-226

LED1
LED2

RS2

RS1

RS+V

W1

Y1

G

R

24V

24V(c)

O

B

*Not used — must be OFF

Not used*

1

2

3

4 min. (on/of

f)

2 min. (on/of

f)

Unlocked

Locked

Standard

Add-on

LED #1 only

LED #1 with filter symbol

LED #2 only

LED #2 with fault symbol

4

5

6

OFF ON

* Important: Switch #4 must be left in OFF position