MicroPak - Introduction

Ransburg

6

LN-9218-00.13

INTRODUCTION

SPECIFICATIONS

(At Sea-Level Conditions)

Environmental / Physical

Electrical Requirements

Power Required:

(per MicroPak)

24 VDC at 2.5A

(fully loaded output),

HP404, RP404, and

HP505 Cascades

28 VDC at 6A

(fully loaded output),

RansPak

1000 (RP1000)

Cascade

GENERAL DESCRIPTION

The

MicroPak

TM

Controller, in conjunction with

an appropriate cascade, is used to provide high

voltage for electrostatic application equipment.

The controller is packaged in a single, 3.2 inch

wide Eurocard module, and thus consumes less

than 1/4 of the available space in a 19 inch rack.

The MicroPak uses a combination of proven high

voltage generation technology including micropro-

cessor-based control with diagnostic and commu-

nication functions. The processor circuitry provides

the maximum in applicator transfer efficiency, while

maintaining the maximum safety when used in

conjunction with FM listed applicators.

SAFETY FEATURES

When used with FM listed applicators, the Micro-

Pak provides the ultimate in operational safety.

The microprocessor circuits allow the use of output

load curve control, which limits the high voltage

output to safe levels, even with the controls set at

maximum levels, and does so without a hard shut

down. The Over current set point, which can be

monitored on the µa Display by pressing the SET

push-button and holding for one second, does pro-

vide a hard shutdown if the output current exceeds

the set point. The kV set point is also displayed

on the kV display when the SET push-button is

pressed for one second.

DISPLAYS

The front panel displays for output voltage and

current indicate the outputs from the cascade of

direct charge applicators or the probe tip voltage

in the case of indirect charge applicators. They are

derived from feedback signals in the low voltage

cable between the controller and the cascade.

Temp. Operating:

(0

o

to 55

o

C)

Storage:

(-40

o

C to 85

o

C)

Humidity:

(95% Non-Condensing)

Size:

100 X 160mm

Eurocard module,

total width 3.2 in.

(one module)

In RansPak

TM

1000 mode, beginning with software

version 3.2, the signal used for the current (µA)

display is conditioned to subtract out the internal

cascade “bleeder” current and thus display the

actual output current.

Note: 24 VDC and 28 VDC power supplies must

be regulated and have overcurrent (40%) and

overvoltage (20%) protection.