DISCRETE OUTPUT
CONFIGURATION
Discrete Output
Word Configuration
Word
0
1
(Not Used)
Discrete Output Bits*
* Reference “Discrete Output Bit
Definition” chart.
HV On Command
HV Reset
Fluid Trigger / Di/dt Delay
Air Trigger
Di/dt Inhibit
MicroPak #1
MicroPak #1
MicroPak #1
MicroPak #1
MicroPak #1
Output
Bit
Module
00
01
02
03
04
DISCRETE OUTPUT BIT DEFINITION
BTW Word
Module
0
1
2
3
4
MicroPak
MicroPak
MicroPak
(Not Used)
Atomizer
High Voltage Setpoint (Value of 0-100 corresponds to 0-100 kV)
Current Limit Setpoint (Value of 0-250 corresponds to 0-250 µA*)
Di/dt Setpoint ( 0 - 9 corresponds to max. to min. sensitivity)
----
Speed Command Liquid (Value of 0-50 corresponds to 0-50 krpm)
Speed Command Powder (Value of 0-150 corresponds to 0-15 krpm)
BLOCK TRANSFER WRITES
BTW Block Configuration
Module
0
1
2
3
4
5
MicroPak
MicroPak
MicroPak
Atomizer
Atomizer
Atomizer
High Voltage Feedback (Value of 0-100 corresponds to 0-100 kV)
Current Feedback (Value of 0-250 corresponds to 0-250 µA
+
)
MicroPak Status Word*
Atomizer Status Word**
Atomizer Drive Pressure (Value of 0-60 corresponds to 0-60 psi)
Atomizer Speed Liquid (Value of 0-50 corresponds to 0-50 krpm)
Atomizer Speed Powder (Value of 0-150 corresponds to 0-15 krpm)
BTR Block Configuration
BLOCK TRANSFER READS
BTR Word
* 0-85 corresponds to 0-85 µA for HP404 FM
0-1000 corresponds to 0-1000 µA for RP1000 or LEPS5002 applications.
* Reference “MicroPak Status Word” table.
** Reference “Atomizer Status Word” table.