MicroPak - Operation

Ransburg

22

LN-9218-00.13

INPUT / OUTPUT SIGNALS (Cont.)

* Status signal available in Node Adapter applications only.

(Input / Output Signals Continued On Next Page)

26A

26C

27C

24A

22A

22C

*

*

*

1A

4A

12A

Signal Description

RED

OR/RED

GRN/BLA

BLA/WH/

RED

OR/GRN

RED/WH

N/A

N/A

N/A

BLA

GRN

BLU

Bell Running - Indicates that Drive air pressure is being supplied to the bell.

High Voltage Ready (HVRDYB) - Indicates interlock is satisfied, High Voltage Reset

is not active and neither Over Current Fault or Feedback Fault is present. In High

Voltage Ready mode, a signal to the High Voltage ON input will cause High Voltage

to come on.

High Voltage On (HVONB) - Indicates High Voltage is on.

Over Current Fault or di/dt Fault (OLB) - Indicates either the DC output current has

exceeded the setpoint or the current rate of rise has exceeded the di/dt sensitivity

setpoint.

Feedback Fault (FBFLTB) - Indicates abnormal signal levels are present on the kV

and/or Current Feedback signals from the cascade.

(See “Diagnostic” in the “Operation” section for a detailed description.)

Local (LOC) - Indicates front panel switch is in “Local” position. In “Local”, the set-

points for kV and Current are received from the front panel controls and not from

remote inputs.

Sequence (SEQB) - Indicates Sequence rotary switch is in a “Non-Zero” position.

(Sequence Mode Timing Diagram is shown in Figure 4.)

Fluid Trigger Active (FLTRIGB) - Indicates the Fluid Trigger output to the EFM gun

is active; applies in both sequenced and non-sequenced modes.

Air Trigger Active (AIRTRIGB) - Indicates Air Trigger output to EFM gun is active.

Overspeed Fault - Indicates module has shut down drive to bell because speed is

10 krpm above setpoint.

Underspeed Fault - Indicates module has shut down drive to bell because speed is

5 krpm under setpoint.

Loss of Feedback Fault - Indicates module has shut down drive to bell because the

maximum time allowed between feedback pulses has been exceeded.

J7 Pin

Wire Color

DISCRETE OUTPUTS

(Contact Ratings: 2 A @ 28 VDC Resistive, 0.5 A @ 120 VAC Resistive,

One Side Common With 30C, White/Black Wire)