beautypg.com

Ransburg, Input / output signals (cont.), Micropak - operation – Ransburg MicroPak LECU5004 User Manual

Page 24: Discrete inputs, Analog outputs (3ma max.)

background image

MicroPak - Operation

Ransburg

21

LN-9218-00.13

High Voltage On (HVON) - If HVRDY is active, supplying 24 VDC causes high

voltage to be present at cascade output.

High Voltage Reset (HVOFF) - Supplying 24 VDC turns off HV, over-riding

HVON signal, or resets fault conditions.

Fluid Trigger (FLTRIG) - Supplying 24 VDC causes fluid trigger to EFM gun to

be active with di/dt activation delayed 5 seconds.

Air Trigger (AIRTRIG) - Supplying 24 VDC causes air trigger to EFM gun to be

active. In Sequence Mode (sequence rotary switch in non-zero position), starts

programmed sequence of air trigger, fluid trigger and HV on.

Di/dt Inhibit - Supplying 24 VDC causes di/dt to be disabled.
Bell Spin Enable - 24 VDC must be supplied to send the speed setpoint to the Atom-

izer. This may also be used as a fault reset, leaving the speed command constant.

DISCRETE INPUTS

(24 VDC Source or Sink Referenced to 18A (WH/BLA/RED), 14A

(RED/GRN), or 13A (BLU/RED)
For Source: Set DIO Module Jumpers E5 and E6 to 2-3

For Sink: Set DIO Module Jumper E5 and E6 to 1-2

BLU/BLA

OR/BLA

RED/BLA

WH/RED

ORG

BLU/WH

J7 Pin

20C

19C

17C

16C

15C

9C

Wire Color

Signal Description

INPUT / OUTPUT SIGNALS (Cont.)

Signal Description

GRN

BLA

WH

BLA

RED

BLA

BLA/RED

High Voltage Output Level (KVFB) - 0-10 VDC=0-100 kV
HV Out Ground (KVFBGND)
Current Output Level (IFB) - 0-10 VDC=0-1000 µA (1000 mode) or

0-10 VDC=0-250µA (HP404, RP404, or HP505 mode)
Current Output Ground (IFBGND)
Atomizer Speed Feedback (see SW2-2 position for scaling)
Speed/Pressure Feedback Ground
Drive Pressure Feedback - 0-10 VDC = 0-100 psi

J7 Pin

14C

17A

6C

8A

7C

7A

8C

ANALOG OUTPUTS (3mA Max.)

Wire Color

(Input / Output Signals Continued On Next Page)