Ransburg, Micropak - operation, Remote / sequenced – Ransburg MicroPak LECU5004 User Manual
Page 17: Front panel
MicroPak - Operation
Ransburg
14
LN-9218-00.13
C A U T I O N
!
W A R N I N G
!
Figure 5b: Sequence Mode Operation (Not for Indirect Charge Mode)
In no case should the J6-3 to 2 jumper be
used with SW3-3 in the OFF position. (This
will turn HV On any time Unit Power is On.)
0
1
2
3
4
5
6
7
8
9
Figure 5a: Sequence Mode Operation
Switch
Setting
Fluid Delay (A)
milliseconds
HV Delay (B)
milliseconds
No Sequence
0
150
250
0
100
150
200
300
400
No Sequence
0
0
0
50
50
50
50
50
50
Be sure that no connection is made to
Motherboard terminal J6-3.
Remote / Sequenced
The same connections apply here as for the Re-
mote mode. If the Sequence Rotary Switch (see
Figure 7) is set to a non-zero position, the HV and
fluid trigger are turned on and off in the sequence
described in Figures 5a & 5b. The sequence is
initiated by activating the air trigger signal when the
sequence rotary switch is in a non-zero position.
Front Panel
When front panel controls are used, SW3-3 can
be set to OFF so that the HV ON mode is always
enabled, meaning that anytime the HV Ready
mode is entered, HV is turned on. This allows
the front panel kV switch to enable the HV Ready
and HV on modes at the same time.