Ransburg, Micropak - operation, Remote / sequenced – Ransburg MicroPak LECU5004 User Manual

Page 17: Front panel

background image

MicroPak - Operation

Ransburg

14

LN-9218-00.13

C A U T I O N

!

W A R N I N G

!

Figure 5b: Sequence Mode Operation (Not for Indirect Charge Mode)

†

In no case should the J6-3 to 2 jumper be

used with SW3-3 in the OFF position. (This

will turn HV On any time Unit Power is On.)

0
1
2
3
4
5
6
7
8
9

Figure 5a: Sequence Mode Operation

Switch

Setting

Fluid Delay (A)

milliseconds

HV Delay (B)

milliseconds

No Sequence

0

150
250

0

100
150
200
300
400

No Sequence

0
0
0

50
50
50
50
50
50

†

Be sure that no connection is made to

Motherboard terminal J6-3.

Remote / Sequenced

The same connections apply here as for the Re-

mote mode. If the Sequence Rotary Switch (see

Figure 7) is set to a non-zero position, the HV and

fluid trigger are turned on and off in the sequence

described in Figures 5a & 5b. The sequence is

initiated by activating the air trigger signal when the

sequence rotary switch is in a non-zero position.

Front Panel

When front panel controls are used, SW3-3 can

be set to OFF so that the HV ON mode is always

enabled, meaning that anytime the HV Ready

mode is entered, HV is turned on. This allows

the front panel kV switch to enable the HV Ready

and HV on modes at the same time.