MicroPak - Maintenance

Ransburg

29

LN-9218-00.13

MAINTENANCE

TROUBLESHOOTING

The Ohm Meter Measurements for HP404, RP404,

HP505 Cascades and RansPak 1000 Cascade

charts are shown in the “Maintenance” section

(see Figures 8 and 9) and will assist in making

Ohm meter measurements through the low voltage

cable for troubleshooting. Note that one table is

for the HP404, RP404, HP505 cascades and

one is for the RansPak 1000 cascade. Also note

that measurements should be taken with the low

voltage cable terminal strip disconnected from

the motherboard.

Troubleshooting Di/dt Faults

Areas to investigate for cause:

• Dirty atomizer interior or exterior

• Conductive solvent residue on atomizer assembly

• Moisture is inside or outside of atomizer body,

causing continuity or partial continuity back to

ground.

• Moisture inside or outside of air lines back to

ground. (High humidity)

• Loose high voltage connections or defective

high voltage cable.

• Loose ground connections or defective ground

connections/wire on atomizer holder or mecha-

nism.

• Dump lines not clean or dry leading back to

ground.

• Target not grounded and causing arcing to ground

from target.

• Di/dt SLP set too sensitive for the application

conditions.

• 24 or 28 VDC DC Power Supply to the Micro-

Pak is unstable.

- Excessive robot tip speed near neighboring parts