Ransburg, Micropak node adapter plc i/o, Micropak - operation – Ransburg MicroPak LECU5004 User Manual

Page 28: Btr module status word, Block transfer reads, Cont.) - micropak mode

background image

MicroPak - Operation

Ransburg

25

LN-9218-00.13

Status

00
01
02
03
04
05
06
07
08
09
10

11

12
13
14
15

HV Held In Reset
HV Ready
HV On
Di/dt Fault
HV Overload
Feedback Fault
Sequence
Local
Fluid Trigger Active
Air Trigger Active
Di/dt Enabled
kV Out of Tolerance
Under Current
Overvoltage
(Not Used)
(Not Used)

Bit

BTR MODULE STATUS WORD

BTR Word

Module

0
1
2
3
4
5
6
7
8
9

10

11

MicroPak #1
MicroPak #1
MicroPak #1
MicroPak #2
MicroPak #2
MicroPak #2
MicroPak #3
MicroPak #3
MicroPak #3
MicroPak #4
MicroPak #4
MicroPak #4

High Voltage Feedback (Value of 0-100 corresponds to 0-100 kV)
Current Feedback (Value of 0-250 corresponds to 0-250 µA *)
Status Word **
High Voltage Feedback (Value of 0-100 corresponds to 0-100 kV)
Current Feedback (Value of 0-250 corresponds to 0-250 µA *)
Status Word**
High Voltage Feedback (Value of 0-100 corresponds to 0-100 kV)
Current Feedback (Value of 0-250 corresponds to 0-250 µA *)
Status Word **
High Voltage Feedback (Value of 0-100 corresponds to 0-100 kV)
Current Feedback (Value of 0-250 corresponds to 0-250 µA *)
Status Word **

BLOCK TRANSFER READS

BTR Block Configuration

MICROPAK NODE ADAPTER PLC I/O

(Cont.)

- MicroPak Mode

* 0-85 corresponds to 0-85 µA for HP404 FM

0-1000 corresponds to 0-1000 µA for RP1000 or LEPS5002 applications.

** Reference “Atomizer Status Word” table.