Ransburg, Micropak node adapter plc i/o, Micropak - operation – Ransburg MicroPak LECU5004 User Manual
Page 28: Btr module status word, Block transfer reads, Cont.) - micropak mode
MicroPak - Operation
Ransburg
25
LN-9218-00.13
Status
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
HV Held In Reset
HV Ready
HV On
Di/dt Fault
HV Overload
Feedback Fault
Sequence
Local
Fluid Trigger Active
Air Trigger Active
Di/dt Enabled
kV Out of Tolerance
Under Current
Overvoltage
(Not Used)
(Not Used)
Bit
BTR MODULE STATUS WORD
BTR Word
Module
0
1
2
3
4
5
6
7
8
9
10
11
MicroPak #1
MicroPak #1
MicroPak #1
MicroPak #2
MicroPak #2
MicroPak #2
MicroPak #3
MicroPak #3
MicroPak #3
MicroPak #4
MicroPak #4
MicroPak #4
High Voltage Feedback (Value of 0-100 corresponds to 0-100 kV)
Current Feedback (Value of 0-250 corresponds to 0-250 µA *)
Status Word **
High Voltage Feedback (Value of 0-100 corresponds to 0-100 kV)
Current Feedback (Value of 0-250 corresponds to 0-250 µA *)
Status Word**
High Voltage Feedback (Value of 0-100 corresponds to 0-100 kV)
Current Feedback (Value of 0-250 corresponds to 0-250 µA *)
Status Word **
High Voltage Feedback (Value of 0-100 corresponds to 0-100 kV)
Current Feedback (Value of 0-250 corresponds to 0-250 µA *)
Status Word **
BLOCK TRANSFER READS
BTR Block Configuration
MICROPAK NODE ADAPTER PLC I/O
(Cont.)
- MicroPak Mode
* 0-85 corresponds to 0-85 µA for HP404 FM
0-1000 corresponds to 0-1000 µA for RP1000 or LEPS5002 applications.
** Reference “Atomizer Status Word” table.