Ransburg, Version 3.8 software, Version 3.9 software – Ransburg MicroPak LECU5004 User Manual

Page 20

background image

MicroPak - Operation

Ransburg

17

LN-9218-00.13

depending on the load, up to the kV Setpoint. The

operation is different than the voltage regulation

mode in that, when the kV Setpoint is reached,

there is no “over-voltage” function and the unit

maintains the output voltage at the setpoint and

allows the current to drop. It stays in this mode

until the load changes such that the current in-

creases up to its setpoint, then it limits at the set-

point and the voltage drops. The big difference

between voltage and current regulation is that the

Current Setpoint is used to set a limit and not an

Over Current shutdown point. The actual Over

Current threshold is set 30% (SW7-5 OFF) above

the Current Setpoint so that in a dynamic situation

where the current can actually rise above the limit

point, the Over Current function is still active.

VERSION 3.8 SOFTWARE

This version adds some switch settings for the

new HP505 cascade. The HP404 settings hav-

ing zero voltage corrections factors (“K”) may be

used for HP505. For voltage correction using the

HP505, switches must be set per Figure 6. Note

that this changes the function of SW7-1 from node

addressing to cascade selection. It is not needed

for node addressing.

VERSION 3.9 SOFTWARE

This version adds appropriate switch settings for

the new RP404 cascade. These can be found

in Figure 6.