Ransburg, Micropak node adapter plc i/o, Input / output signals – Ransburg MicroPak LECU5004 User Manual
Page 26: Micropak - operation, Micropak mode, Discrete output configuration, Cont.), Discrete outputs (cont.)
![background image](/manuals/348116/26/background.png)
MicroPak - Operation
Ransburg
23
LN-9218-00.13
MICROPAK NODE ADAPTER PLC I/O
- MicroPak Mode
----
Di/dt Inhibit
Di/dt Inhibit
Di/dt Inhibit
Di/dt Inhibit
----
HV On Command
HV Reset
Fluid Trigger / Di/dt Delay
Air Trigger
HV On Command
HV Reset
Fluid Trigger / Di/dt Delay
Air Trigger
HV On Command
HV Reset
Fluid Trigger / Di/dt Delay
Air Trigger
HV On Command
HV Reset
Fluid Trigger / Di/dt Delay
Air Trigger
(Not Used)
MicroPak #1
MicroPak #2
MicroPak #3
MicroPak #4
(Not Used)
MicroPak #1
MicroPak #1
MicroPak #1
MicroPak #1
MicroPak #2
MicroPak #2
MicroPak #2
MicroPak #2
MicroPak #3
MicroPak #3
MicroPak #3
MicroPak #3
MicroPak #4
MicroPak #4
MicroPak #4
MicroPak #4
Bit
Module
0/00-07
0/10
0/11
0/12
0/13
0/14-17
1/00
1/01
1/02
1/03
1/04
1/05
1/06
1/07
1/10
1/11
1/12
1/13
1/14
1/15
1/16
1/17
DISCRETE OUTPUT CONFIGURATION
Output
INPUT / OUTPUT SIGNALS
(Cont.)
* Status signal available in Node Adapter applications only.
23C
24C
25C
31A
Signal Description
BLA/WH
GRN/WH
GRN/BLA/WH
R/BLA/WH
Invalid Data Fault - Indicates module has shut down drive to bell because
speed setpoint is above the operating range of the bell.
Low Bearing Air Fault - Indicates module has shut down drive to bell because
bearing air pressure is below the level set by Serial Atomizer switch SW2-7 and -8.
Speed out of Tolerance - Indicates bell speed is outside the window of
±5% of setpoint. This is a status signal only and does not shut down drive to bell.
24 VDC utility output, may be used to power relay contact common (30C),
0.1 Amps Max.
J7 Pin
Wire Color
DISCRETE OUTPUTS (Cont.)
(Contact Ratings: 2 A @ 28 VDC Resistive, 0.5 A @ 120 VAC Resistive,
One Side Common With 30C, White/Black Wire)