Aerbell 33 Rotary Atomizer - Maintenance

Ransburg

24

LN-9521-00.4

†

The protective disposable wrap is for

one time use only. Do not wash and reuse

the wrap.

NOTE

†

Normally the wrap will not need re-

placement daily and could last about one

week. See "Weekly Maintenance" in the

"Maintenance" section.

NOTE

†

Maximum flow rate should not exceed

500 cc/minute.

C A U T I O N

!

• Wait for rotation to cease and then clean off bell

cup edge and shaping air ring and any other

outer surfaces. Use a soft cloth dampened with

solvent.

• Visually inspect the bell cup edge for signs of

abrasion. If the coating is excessively worn

back (1/16 inch or more) or badly chipped as

the result of contact with a part, replace the cup.

• Check bell cup voltage using high voltage

probe. Voltage should be approximately 85

kV when 100 kV is set on the power supply.

• Check the amount of paint build up on the outer

protective wrap. If excessive, replace wrap as

required.

W A R N I N G

†

Do not place high voltage probe on bell

edge unless rotation is fully stopped.

!

W A R N I N G

†

In the event the bell cup comes in con-

tact with a part, that cup should be checked

for damage and replaced if necessary be-

fore continuing to spray.

!

Weekly Maintenance

(Prior to Start or End of Production Week)

†

Refer to the "Troubleshooting Guide"

(Figure 15) for details on determining the

causes of low or no high voltage at the bell cup.

NOTE

• Monitor rotational speed of all bells at the speed

control (should be within approximately 5% of

target speed).

• Monitor high voltage output indicated on the

display of the control unit or at the meter of the

power supply (should be within approximately

5% of target output).

• Check paint flow on all bells at minimum and

maximum specified settings by taking beakered

readings.

• Check solvent flow by opening solvent valve

and taking a beakered reading (should be within

approximately 10% of target flow rate).

• Remove protective wrap from outer housing

and discard. Clean any paint on outer surface

of front and rear housing with soft cloth damp-

ened with solvent. (See “Warning” under “Daily

Maintenance” on avoiding the use of cleaning

solvent containing d-Limonene.)