Specifications, Turbodisk applicator - introduction, Paint valve options – Ransburg Turbodisk Applicator Assembly A11376 User Manual
Page 11: Power supply and controls, Mechanical, Electrical
![background image](/manuals/348093/11/background.png)
Turbodisk Applicator - Introduction
6
Paint Valve Options
Several valve options are available for both single
and dual feed.
Options are:
• No Valves
• 3-Way Valves
• Trigger and Dump Valves with DR-1 Regulator
• Trigger Valve Only
• Trigger and Dump Valves with Dual DR-1
Regulators
• Trigger Valves with DR-1 Regulator
Power Supply and Controls
In the system, the high voltage is supplied to the
Turbodisk by either the MicroPak™ Industrial power
supply system or a Voltage Master™ series power
supply.
The MicroPak Industrial power supply uses proven
high voltage generator technology that is micro-
processor controlled for diagnostics and communi-
cation. The controller is packaged in standard rack
mounted Eurocard format for easy access and system
integration.
The Voltage Master™ power supplies are general
purpose heavy duty power supplies with years of
proven reliability. They have variable voltage control,
many safety features, and remote analog voltage
control capabilities.
SPECIFICATIONS
Turbine Speed:
Variable to 40,000 rpm
max. (6-inch conical disk)
Turbine Type:
Ball Bearing
Weight:
57-lbs. (approximately)
Length:
36-inches
Diameter:
13.25-inches
Turbine Air:
At max. speed (40k rpm),
requires 103.1 psi and
61.1 SCFM, unloaded
(See "Typical Speed Chart"
in this section.)
Air Temp
°F:
120
°F maximum at
applicator
Fluid Pressure
Inlet:
(See "Fluid and Air Pressure Regulator"
in the "Operation" section.)
Single Fluid Flow Range:
Waterborne:
To 1,200 cc/min. maximum
Solvent Base:
To 1,500 cc/min. maximum
High Solids:
To 1,000 cc/min. (80%+)
maximum
Air Inlet
Trigger / Dump:
70-100 psi
Air Pilot for Fluid
Pressure:
(See "Fluid and Air Pressure Regu-
lator" in the "Operation" section.)
Mechanical
Power Supply
Type:
MicroPak Industrial or
Voltage Master
TM
Charging Method:
Direct
Input Voltage:
0-100 kV
Turbine Speed
Control or Monitor:
PulseTrack 2(Optional)
Electrical
AA-07-02.1