C-25 timer control instructions – Kasco Marine Pond Aerator & Water Circulator User Manual
Page 14
14
DOES POP OUT, OR IF THE G.F.C.I. FAILS TO RE-
SET PROPERLY, DO NOT USE TIMER! CONTACT A
QUALIFIED SERVICE TECHNICIAN!
UNDER NO CIRCUMSTANCES SHOULD ANYONE
ENTER THE WATER WHEN A UNIT IS IN OPERA-
TION!
TIMER-OPERATION INSTRUCTIONS
C-25 Control Box will turn the aerator ON & OFF with the
TIMER. Kasco lights will turn ON with the PHOTO EYE
and OFF with TIMER. C-25 Control Box is to be used
with Kasco Approved Lights ONLY!
• Insert “ON” (GREEN) and “OFF” (RED) trippers into
dial at desired ON and OFF times.
• Turn dial clockwise one or more revolutions until
correct time-of-day (AM or PM) in window is aligned
with the arrow.
• Plug aerator cord into the RIGHT hand outlet (labeled
UNIT).
• Plug transformer light cord into LEFT hand outlet
(labeled LIGHT).
FOR TEMPORARY MANUAL OPERATION
Rotate MANUAL knob counter-clockwise to desired ON or
OFF position. Timer will follow next automatic operation.
Record the following data while the Aerator is operating
in the water under load:
Voltage:
L1-L2 ________
L1-N _________
L2-N _________
Amperage:
L1 __________
L2 __________
Date installed _____/_____/_____
Any unauthorized modifications to this control panel will
void the UL listing and the Kasco warranty.
C-25 Timer Control Instructions
(Optional Equipment)
Portable Timer with Ground Fault Interrupter
IMPORTANT
This portable timer is designed for CONTROLLING the
connected equipment only. Unplug timer before servic-
ing the unit or the equipment it controls. THE MANUAL
OVERRIDE KNOB IS NOT TO BE USED AS A POWER
DISCONNECT! For maximum protection against electri-
cal shock hazard, perform test procedure on G.F.C.I. at least
once a month. Mount at least 5 ft. from open water.
G.F.C.I. TEST PROCEDURE
The G.F.C.I. should be checked every month to make sure
that it is operating properly. Just follow the simple instruc-
tions below. It is recommended to maintain a maintenance
diary of your monthly safety check.
1. Push TEST button, RESET button should pop out from
inner surface. This should result in power being OFF at
the outlet protected by the G.F.C.I. Verify by plugging a
test lamp into the outlet. Be sure the timer is in the ON
position.
2. If the G.F.C.I. tests okay, restore power by pushing the
RESET button back in. THE RESET BUTTON MUST BE
PUSHED FIRMLY AND FULLY INTO PLACE UNTIL IT
LOCKS AND RE-MAINS DEPRESSED AFTER PRES-
SURE HAS BEEN REMOVED.
DANGER: IF RESET BUTTON DOES NOT POP OUT,
IF TEST LAMP REMAINS LIT WHEN RESET BUTTON