beautypg.com

Kasco Marine C95 DISPLAY AERATOR CONTROL User Manual

Model: c95, Important

background image

MODEL: C95

DISPLAY AERATOR CONTROL WITH TIME SWITCH, GFCB,

LIGHTNING ARRESTOR AND 15 AMP GFCI LIGHTING RECEPTACLE

SUITABLE FOR USE WITH SUBMERSIBLE LIGHTS

IN RAINPROOF (TYPE 3R) ENCLOSURE SUITABLE FOR INDOOR OR OUTDOOR USE

40 AMP. MAX PER LEG 120/240 VOLT SINGLE PHASE (THREE WIRE) AC

PUMP CIRCUIT: 24 FLA, 144 LRA, 240 Vac, LIGHT CIRCUIT: 120 Vac - 15 amp Max.

MIN. 75˚ C SUPPLY CONDUCTORS

PHOTO CONTROL RATINGS: 120 VAC 50/60 HZ. 1800W TUNGSTEN, 8.3A BALLAST

LIGHTNING ARRESTOR RATINGS: 120/240 VAC; MCOV 250 VAC

TIME SWITCH OPERATING INSTRUCTIONS

1. TO SET “ON” AND “OFF” TIMES:

Hold TRIPPERS against edge of

CLOCK-DIAL, pointing to time (AM or

PM) when

ON and OFF operations are

desired. Tighten tripper screws firmly.

2. TO SET TIME-OF-DAY:

Pull CLOCK-DIAL outward. Turn in

either direction and align the exact time-

of-day on the CLOCK-DIAL (the time

now, when switch is being put into

operation) to the pointer.

-DO NOT MOVE POINTER-

TO OPERATE SWITCH MANUALLY: Move MANUAL-LEVER

below left or right as indicated by arrows. This will not affect the

next operation.

FOR MORE THAN ONE DAILY ON-OFF OPERATION:

Place additional tripper pairs on CLOCK-DIAL (order

156T1978A).

IN CASE OF POWER FAILURE: Reset CLOCK-DIAL to proper

time of day. See step 2 above.

ON

TRIPPER

TIME

POINTER

TIME

DIAL

OFF

TRIPPER

MANUAL

LEVER

Wiring information-Copper

Conductors
Wire

Terminal

Size

Tightening Torque

AWG

Lb-In

14

20

12

20

10

20

8

25

6

35

4

45

3

50

2

50

IMPORTANT:

This control panel must be installed

according to the National Electrical Code (including

article 680) and local code requirements. The main

lugs and neutral main are suitable for No. 14 to 2 AWG

COPPER conductors. Follow gauge selection table and

corresponding terminal screw tightening torque require-

ments below. An additional branch circuit protector (20 Amp

max) may be installed in the unused position for use as an

auxiliary circuit. Use only Square D HOM Series circuit

breakers for addition or replacement (do not exceed rat-

ings on wiring diagram). Follow Manufacturers instructions

for testing of ground fault circuit breakers (GFCB). This

panel is equipped with a 120V AC - 15 amp duplex GFCI

receptacle for connecting a 120V AC light kit or an external

low voltage transformer for lighting. The Pump Terminal Bar

is controlled by the timer only. The Lighting GFCI outlet is

controlled by the timer and photoelectric circuit. Refer to the

instructions provided with your light kit. After wiring, install

front panel over wiring compartment.

KEEP DOOR CLOSED AT ALL TIMES.

KASCO MARINE, INC.,

800 Deere Road
Prescott, WI 54021-1241
Phone (715) 262-4488

UL508

UL1563

NEC 680

LR3730

T30004R31

PUMP CIRCUIT

158PS13206

30 A

OPEN (20 A)