Kasco Marine Pond Aerator & Water Circulator User Manual
Page 13
13
building, or other reliable means. This structure must
support the panel and prevent movement/flexing of the
panel. Use #10 x 1” or longer screws in the mounting
points of the control panel to secure to the post structure.
NOTE: The control panel must be hung upright in order to
be waterproof. It is also advised to mount the panel out of
direct sunlight if possible. Mounting the panel in a North
direction will prevent heat buildup inside the panel. Also,
mount the panel above the potential flood plain to prevent
water entry during a possible flood event.
STEP TWO
Set Timer in the control panel to desired ON and OFF times
per the Instructions for each specific timer.
STEP THREE
Follow all local and national electrical codes for this
installation and Consult a qualified electrician or service
person if needed.
(For 120V Installations)
Plug the aerator cord into the C-25 outlet labeled “UNIT”.
If lights are included, plug the Transformer cord into the
C-25 outlet labeled “LIGHT”. Now you are ready to plug
the C-25 into the 120V power supply on the post and EN-
JOY YOUR NEW KASCO AERATOR!
3 Phase: (2.3, 3.3, 5.3)
Refer to your 3 phase control panel instructions
Single Phase: (3400H, 4400H, 8400, 3.1, 5.1)
STEP THREE (For 240V Installation)
All electrical connections to this panel must be made
with proper strain relief cord grip fittings or with conduit
connections as required by local and national electric codes.
The bottom of the enclosure is reserved for field installation
of these connections.
C85 / C95 non-metallic control panel:
Incoming power connection: (Power feed)
This control panel requires a 240V or 208V - 4 wire service
(L1, L2, N, & G) and must be fed with a power circuit
protected by a circuit breaker or a fused disconnect switch
to provide circuit protection and a disconnection means.
C-85 panel requires at least a 30amp protected circuit
feeding the panel.
C-95 panel requires at least a 40amp protected circuit
feeding the panel.
Connect your power feed as detailed in the wiring diagram
provided with this panel.
L1 connects to Terminal
#1
L2 connects to Terminal
#2
N connects to Terminal N
G connects to Terminal GROUND - located on
chassis
plate
Be sure to provide adequate sized power conductors
to prevent excessive voltage drop. Consult with your
electrician to properly size power feed conductors. Use
copper conductors only.
Aerator power cord connection:
Your aerator (pump) will be provided with a flexible power
cord for connection to this control panel. If the power cord
has a plug, you will need to cut it off. The power cord
conductors (black, white, green) will need to be stripped
back 1/2”. The outer black jacket should be stripped
back at least 3inches. Follow the connection diagram for
terminating these three wires to the terminal blocks in the
control panel.
Black connects to Terminal
#4
White connects to Terminal
#5
Green connects to Terminal
G
Light Kit connection:
If you purchased a Kasco light kit(s) for your aerator,
follow the light kit installation instructions for mounting
the light kit(s) to the aerator float.
This control panel requires a hardwire connection for
the light kit(s). To connect the light kit(s) you will need
to cut off the power cord plug that is molded to the light
kit power cord. Strip back the black outer jacket of the
light kit power cord at least 3inches to reveal the three
internal wires of the power cord. (black, white, and green
conductors). These three wires will need to be stripped
back 1/2”. Follow the connection diagram for terminating
these three wires to the terminal blocks in the control panel.
Light kit connections:
Black connects to Terminal
#6
White connects to Terminal
#7
Green connects to Terminal
G
STEP FOUR:
Test the GFCB with the test button now and every 30
days.
If lights are installed, they can now be installed per Instruc-
tions included with the lights.
Once completed, power can be restored to the panel.