OPERATING & MAINTENANCE TIPS
Never insert the probe into a fuel tank or a flammable liquid or gas such as
unleaded gasoline, diesel fuel, machine oil, DOT 4 brake fluid or transmission
fluid.
The probe contains thin wires running along its entire length. Accordingly,
handle it with care:
• Do not bend it more than 90° anywhere along its length.
• Do not bend the probe more than 70° within 1.2 in. (30mm) of its camera tip.
• Do not bundle the probe into a tight circle to store it.
• Never use the camera end to clear its own path of debris.
• Do not overtighten the collar that secures the probe to the handle.
To clean the camera lens and LEDs, use a cotton swab and a small amount of
mild detergent.
The grip requires no routine maintenance other than periodic cleaning with a
soft, dry cloth. Never use a wet cloth, corrosive liquids, solvents or water. Avoid
getting the grip wet.
Operate and store iBorescope only in a cool (under 140°F or 60°C), dry, well-
ventilated place. Avoid exposing the unit to sunlight for long periods of time.
iBorescope is designed for industrial and environmental use only. Never use it
for human or any other biological inspection.
WARRANTY INFORMATION
General Tools & Instruments’ (General’s) DCiS1 iBorescope is warranted to the
original purchaser to be free from defects in material and workmanship for a
period of one year. Subject to certain restrictions, General will repair or replace
this instrument if, after examination, the company determines it to be defective
in material or workmanship.
This warranty does not apply to damages that General determines to be from
an attempted repair by non-authorized personnel or misuse, alterations, normal
wear and tear, or accidental damage. The defective unit must be returned to
General Tools & Instruments or to a General-authorized service center, freight
prepaid and insured.
19